Zirconia Implants as an Alternative to Titanium: A Systematic Review and Meta-Analysis.
نویسندگان
چکیده
PURPOSE The aim of the present study was to systematically evaluate the marginal bone loss (MBL), success, and survival of zirconia (Zi) implants and compare them with the widely studied titanium (Ti) implants. MATERIALS AND METHODS An electronic and manual literature search of several databases was performed by two independent reviewers for articles up to July 2015 that reported the use of Zi implants and survival, success, and MBL with at least 12 months' follow-up. In addition, random effects meta-analyses of selected studies were applied to analyze the weighted mean difference of survival, success, and MBL between groups. Meta-regression analysis was conducted to investigate any potential influence of confounding factors. RESULTS Twenty-one articles were included, analyzing a total of 1,948 Zi implants with a survival rate of 91.5% and a success rate of 91.6% for 1,250 Zi implants. In addition, three studies were included in the quantitative synthesis and were meta-analyzed for the comparison of survival between Zi and Ti implants, with Zi implants having an 89% greater risk of failure compared with Ti implants (OR = 1.89). There were no statistically significant differences (P = .968) in the success of Zi and Ti implants (odds ratio [OR] = 1.02; 95% confidence interval [CI], 0.47-2.20). MBL (± SD) for Zi implants was 0.89 ± 0.18 mm, which was greater than the MBL for Ti implants (mean difference = 0.14 mm). Also, survival of Zi implants (91.5%) was significantly lower than that of Ti implants (OR = 1.89). Metaregression analysis revealed a similar survival rate for one-piece versus two-piece implants. Similarly, no significant differences were found between immediate and delayed loading. CONCLUSIONS The survival rate of Zi implants was significantly lower than that for the commonly used Ti implants. However, for certain clinical conditions, such as a thin tissue biotype or in the highly esthetic anterior area, Zi implants may offer some benefit when compared with Ti implants.
منابع مشابه
Effect of Zirconia Dental Implant Surfaces on Bone Integration: A Systematic Review and Meta-Analysis
Background. The information available about osseointegration and the bone to implant interaction of zirconia implants with various surface modifications is still far from sufficient. Objective. The purpose of this systematic review and meta-analysis was to evaluate and compare zirconia dental implants with different surface topographies, with a focus on bone to implant contact and removal torqu...
متن کاملAre ceramic implants a viable alternative to titanium implants? A systematic literature review.
AIM The aim of this systematic review was to screen the literature in order to locate animal and clinical data on bone-implant contact (BIC) and clinical survival/success that would help to answer the question 'Are ceramic implants a viable alternative to titanium implants?' MATERIAL AND METHODS A literature search was performed in the following databases: (1) the Cochrane Oral Health Group's...
متن کاملInfluence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis
Purpose To compare the failure events and incidence of complications of different abutment materials in anterior and posterior regions. Failure was defined as complete loss of the abutment requiring replacement by a new abutment. Materials and methods Electronic searches using PubMed/Medline and Google Scholar complemented with manual searches were performed with specific search terms. Search...
متن کاملCrestal bone loss and periimplant inflammatory parameters around zirconia implants: A systematic review.
STATEMENT OF PROBLEM Zirconia implants have been used for oral rehabilitation; however, evidence of their ability to maintain crestal bone and periimplant soft tissue health is not clear. PURPOSE The purpose of this systematic review was to evaluate crestal bone loss (CBL) around zirconia dental implants and clinical periimplant inflammatory parameters. MATERIAL AND METHODS The focus questi...
متن کاملOsseointegration of zirconia implants with different surface characteristics: an evaluation in rabbits.
PURPOSE Zirconia ceramics are a viable alternative to titanium for use as dental implants. However, the smooth surface of zirconia means that longer healing periods are needed to accomplish osseointegration compared to roughened titanium surfaces. Surface modifications can be used to increase the roughness of zirconia. The aim of this study was to assess histologically and compare the degree of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 32 3 شماره
صفحات -
تاریخ انتشار 2017