Size-specific dose estimates for adult patients at CT of the torso.

نویسندگان

  • Jodie A Christner
  • Natalie N Braun
  • Megan C Jacobsen
  • Rickey E Carter
  • James M Kofler
  • Cynthia H McCollough
چکیده

PURPOSE To determine relationships among patient size, scanner radiation output, and size-specific dose estimates (SSDEs) for adults who underwent computed tomography (CT) of the torso. MATERIALS AND METHODS Informed consent was waived for this institutional review board-approved study of existing data from 545 adult patients (322 men, 223 women) who underwent clinically indicated CT of the torso between April 1, 2007, and May 13, 2007. Automatic exposure control was used to adjust scanner output for each patient according to the measured CT attenuation. The volume CT dose index (CTDI(vol)) was used with measurements of patient size (anterioposterior plus lateral dimensions) and the conversion factors from the American Association of Physicists in Medicine Report 204 to determine SSDE. Linear regression models were used to assess the dependence of CTDI(vol) and SSDE on patient size. RESULTS Patient sizes ranged from 42 to 84 cm. In this range,CTDI(vol) was significantly correlated with size (slope = 0.34 mGy/cm; 95% confidence interval [CI]: 0.31, 0.37 mGy/cm; R(2) = 0.48; P < .001), but SSDE was independent of size (slope = 0.02 mGy/cm; 95% CI: -0.02, 0.07 mGy/cm; R(2) = 0.003; P = .3). These R(2) values indicated that patient size explained 48% of the observed variability in CTDI(vol) but less than 1% of the observed variability in SSDE. The regression of CTDI(vol) versus patient size demonstrated that, in the 42-84-cm range, CTDI(vol) varied from 12 to 26 mGy. However, use of the evaluated automatic exposure control system to adjust scanner output for patient size resulted in SSDE values that were independent of size. CONCLUSION For the evaluated automatic exposure control system,CTDI(vol) (scanner output) increased linearly with patient size; however, patient dose (as indicated by SSDE) was independent of size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An easy method to create the better representative of patients with various body morphologies

Introduction: In recent years, there has been increasing demand for personalized anatomy modeling for medical applications, because the influence of phantoms on the quality of treatments and precision dosimetry has been specified. Phantoms have many applications on medical such as treatment planning, diagnostic imaging, clinical radiological exposure simulation, and biomechanic...

متن کامل

Radiation dose of Pediatrics in a general hospital in comparison to a pediatrics hospital

Introduction: Increasing CT scan application increased the cancer risk in pediatrics in recent decays. Imaging centers approach for diagnosis of disease cause to different radiation dose to patients.  Because  of  rapid  pediatrics  body  growth,  the  most  important  challenge to determining the radiation dose is wide variations of size in different ages. Thus, we used Size...

متن کامل

A comparison of 2D and 3D kidney absorbed dose measures in patients receiving 177Lu-DOTATATE

Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...

متن کامل

Estimation of Mean Patient Dose Indices in Chest and Abdomen/Pelvis CT Examinations in Rafsanjan Ali Ibn Abitalib Hospital in 2018: A Descriptive Study

Background and Objectives: The radiation protection of patients in CT examinations is important due to its wide application and high contribution in collective dose of public, and its radiation effects. The purpose of this study was to estimate the mean patient dose indices in chest and abdomen/pelvic examinations as the first step in patient radiation protection process. Materials and Methods...

متن کامل

Effect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations

Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 265 3  شماره 

صفحات  -

تاریخ انتشار 2012