Remote control catheter navigation: options for guidance under MRI

نویسندگان

  • Leah Muller
  • Maythem Saeed
  • Mark W Wilson
  • Steven W Hetts
چکیده

BACKGROUND Image-guided endovascular interventions have gained increasing popularity in clinical practice, and magnetic resonance imaging (MRI) is emerging as an attractive alternative to X-ray fluoroscopy for guiding such interventions. Steering catheters by remote control under MRI guidance offers unique challenges and opportunities. METHODS In this review, the benefits and limitations of MRI-guided remote control intervention are addressed, and the tools for guiding such interventions in the magnetic environment are summarized. Designs for remote control catheter guidance include a catheter tip electromagnetic microcoil design, a ferromagnetic sphere-tipped catheter design, smart material-actuated catheters, and hydraulically actuated catheters. Remote control catheter guidance systems were compared and contrasted with respect to visualization, safety, and performance. Performance is characterized by bending angles achievable by the catheter, time to achieve bending, degree of rotation achievable, and miniaturization capacity of the design. Necessary improvements for furthering catheter design, especially for use in the MRI environment, are addressed, as are hurdles that must be overcome in order to make MRI guided endovascular procedures more accessible for regular use in clinical practice. CONCLUSIONS MR-guided endovascular interventions under remote control steering are in their infancy due to issues regarding safety and reliability. Additional experimental studies are needed prior to their use in humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Remote Control of Catheter Tip Deflection: A Special Opportunity for Interventional MRI

One of the challenges of endovascular interventional procedures is to direct the remote catheter tip into tiny blood vessel branches in the brain, or heart, for example. Conventional approaches to this problem have involved development of catheter materials, tip geometries and the “hands-on” exact skill of the interventional practitioner. While these procedures are generally performed under ima...

متن کامل

Dynamically shaped magnetic fields: initial animal validation of a new remote electrophysiology catheter guidance and control system.

BACKGROUND To address some of the shortcomings of existing remote catheter navigation systems (RNS), a new magnetic RNS has been developed that provides real-time navigation of catheters within the beating heart. The initial experience using this novel RNS in animals is described. METHODS AND RESULTS A real-time, high-speed, closed-loop, magnetic RNS system (Catheter Guidance Control and Imag...

متن کامل

Endovascular catheter for magnetic navigation under MR imaging guidance: evaluation of safety in vivo at 1.5T.

BACKGROUND AND PURPOSE Endovascular navigation under MR imaging guidance can be facilitated by a catheter with steerable microcoils on the tip. Not only do microcoils create visible artifacts allowing catheter tracking, but also they create a small magnetic moment permitting remote-controlled catheter tip deflection. A side product of catheter tip electrical currents, however, is the heat that ...

متن کامل

Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation.

BACKGROUND Catheters are typically stiff and incorporate a pull-wire mechanism to allow tip deflection. While standing at the patient's side, the operator manually navigates the catheter in the heart using fluoroscopic guidance. METHODS AND RESULTS A total of 42 patients (32 female; mean age, 55+/-15 years) underwent ablation of common-type (slow/fast) or uncommon-type (slow/slow) atrioventri...

متن کامل

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures

New remote navigation systems have been developed to improve current limitations of conventional manually guided catheter ablation in complex cardiac substrates such as left atrial flutter. This protocol describes all the clinical and invasive interventional steps performed during a human electrophysiological study and ablation to assess the accuracy, safety and real-time navigation of the Cath...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012