Efficiency of airway heat and moisture exchangers in anesthetized humans.

نویسندگان

  • P E Bickler
  • D I Sessler
چکیده

The efficiencies of airway heat and moisture exchanging filters in reducing respiratory water losses and increasing airway temperatures during general anesthesia were studied in five tracheally intubated patients given isoflurane, nitrous oxide, and oxygen anesthesia during controlled ventilation. Filters (Humid-Vent Filter, Humid-Vent 1, Pall Conserve, Siemens 150, and ThermoVent 600) were placed between the Y-piece of the anesthesia circle system and the endotracheal tube for 40 min each. Airway temperature, esophageal temperature, and water loss (determined by weighing expired water collected in CaSO4) were measured every 10 min. All of the filters reached near-maximum efficiency in reducing water losses within 10 min. The Humid-Vent Filter and Siemens 150 filters were most efficient, the Pall Conserve and ThermoVent 600 less efficient. Airway temperature rapidly increased 2 degrees-8 degrees C during each trial. The more efficient the filter in conserving water, the greater the airway temperature. The respiratory heat conserved by these filters represents 5.5%-7.2% of the estimated total metabolic heat production during anesthesia in adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating Humidity Recovery Efficiency of Currently Available Heat and Moisture Exchangers: A Respiratory System Model Study

OBJECTIVES To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. INTRODUCTION Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute h...

متن کامل

Multi-objective optimization of two hybrid power generation systems for optimum selection of SOFC reactants heat exchangers mid-temperatures

Increasing efficiency and decreasing cost are the main purposes in the design of the power generation systems. In this study two hybrid systems: solid oxide fuel cell (SOFC)-gas turbine (GT) and SOFC-GT-steam turbine (ST); are considered. Increasing the SOFC input temperature causes thermodynamics improvement in the hybrid system operation. For this purpose, using two set of SOFC reactants heat...

متن کامل

Ventilatory changes during the use of heat and moisture exchangers in patients submitted to mechanical ventilation with support pressure and adjustments in ventilation parameters to compensate for these possible changes: a self-controlled intervention study in humans

OBJECTIVE To evaluate the possible changes in tidal volume, minute volume and respiratory rate caused by the use of a heat and moisture exchanger in patients receiving pressure support mechanical ventilation and to quantify the variation in pressure support required to compensate for the effect caused by the heat and moisture exchanger. METHODS Patients under invasive mechanical ventilation i...

متن کامل

The Effects of Aerosol Drug Delivery on Airway Resistance through Heat-Moisutre Exchangers

THE EFFECT OF AEROSOL DRUG DELIVERY ON AIRWAY RESISTANCE THROUGH HEAT-MOISTURE EXCHANGERS (HMEs) By Matthew Hart Introduction: The use of heat moisture exchangers (HMEs) is becoming more popular with many institutions delivering aerosolized medications between the HME and the endotracheal tube of patients being mechanically ventilated. When HMEs become saturated resistance can increase which ca...

متن کامل

In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.

BACKGROUND Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 71 4  شماره 

صفحات  -

تاریخ انتشار 1990