Probes Vacillating and Mapping Technique at Testing Micro-area Sheet Resistance

نویسندگان

  • Zhihui Zhu
  • Xinfu Liu
  • Runli Zhang
  • Nan Jiang
چکیده

This article briefly elaborated the basic concepts of the probe vacillated at testing a large silicon wafer with square four point probe equipment. The importance of the micro-area’s sheet resistance is discussed and the basic principles of four point probe measurement technology are analyzed. Some factors that affect the measurement accuracy are studied, and interference can be avoided while measuring and analyzing the impact on square four point probe measurement by probe vacillate. The calculation formula of the square micro-area probe measurement is deduced when probes vacillated discretionarily. An experiment was made with a small wafer sample and accurate resistivity was gotten. The electrical resistivity is tested for another silicon wafer by a square four point probe equipment. Color Mapping graphics was designed for displaying the micro-area resistance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dispersive liquid-liquid microextraction using silver nanoparticles as electrostatic probes for preconcentartion and quantitative analysis of terazosin

An efficient dispersive liquid-liquid microextraction using tetraalkylammonium bromide coated silver nanoparticles (DLLME-AgNPs) prepared in chloroform has been successfully applied as electrostatic affinity probes to the microextraction and preconcentration of terazosin prior to spectrofluorimetry analysis. This technique is based on a ternary system of solvents, where appropriate amount of mi...

متن کامل

Magnetic force microscopy using fabricated cobalt-coated carbon nanotubes probes

Magnetic force microscope ( MFM ) is a powerful technique for mapping the magnetic force gradient above the sample surface. Herein, single-wall carbon nanotubes (SWCNT) were used to fabricate MFM probe by dielectrophoresis method which is a reproducible and cost-effective technique. The effect of induced voltage on the deposition manner of carbon nanotubes (CNT) on the atomic force microscope (...

متن کامل

Probes for Monitoring Low Dose Silicon Ion Implants for Process Yield Enhancement

A newly developed optical densitometry probe, and existing thermal wave, eddy current sheet resistance, and four-point GaAs sheet resistance probes were used to measure low dose Si+ ion implams. The four probes were evaluated for their ability to detect implant dose uniformity, their sensitivity to low doses, and their repeatability for multiple measurements on a single wafer, and on several wa...

متن کامل

Dispersive liquid-liquid microextraction using silver nanoparticles as electrostatic probes for preconcentartion and quantitative analysis of terazosin

An efficient dispersive liquid-liquid microextraction using tetraalkylammonium bromide coated silver nanoparticles (DLLME-AgNPs) prepared in chloroform has been successfully applied as electrostatic affinity probes to the microextraction and preconcentration of terazosin prior to spectrofluorimetry analysis. This technique is based on a ternary system of solvents, where appropriate amount of mi...

متن کامل

Accurate microfour-point probe sheet resistance measurements on small samples.

We show that accurate sheet resistance measurements on small samples may be performed using microfour-point probes without applying correction factors. Using dual configuration measurements, the sheet resistance may be extracted with high accuracy when the microfour-point probes are in proximity of a mirror plane on small samples with dimensions of a few times the probe pitch. We calculate theo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013