Effects of a Schlemm canal scaffold on collector channel ostia in human anterior segments.

نویسندگان

  • Murray A Johnstone
  • Hady Saheb
  • Iqbal Ike K Ahmed
  • Thomas W Samuelson
  • Andrew T Schieber
  • Carol B Toris
چکیده

This study evaluates the morphologic effect of the implantation of two different sizes of the Hydrus microstent on the outer wall of Schlemm's canal (SC) and collector channel (CC) ostia. Twelve human eyes were dissected at the equator removing the iris, lens, ciliary body and vitreous. The cornea was excised with a corneal trephine exposing a direct view of the angle while leaving the trabecular meshwork (TM) intact. The Hydrus delivery system was used to deliver microstents of 8 mm and 15 mm in length into SC. Following delivery, the tissues were immediately immersed in fixative. After tissue fixation, the microstents were gently lifted out of SC through the TM leaving a small slit opening in the TM. The slit opening was widened by gently dissecting the entire TM. Control eyes underwent dissection before fixation by gently removing the TM exposing the outer wall of SC. The tissues were prepared for scanning electron microscopy (SEM). The external wall of SC was imaged using SEM and were reviewed with particular attention focused on the distribution of irregular particulate matter (IPM), the shape of the CC ostia and the health of the SC endothelium. Three eyes received the 8 mm microstent, two the 15 mm microstent and 6 eyes served as controls. Five of the controls had reported histories of glaucoma while all other eyes were normal. All eyes showed evidence of removal of the trabecular meshwork revealing the external wall of SC. CCs were regularly visible in all eyes and were not obstructed, compressed or their margins disrupted. Nuclear profiles were oriented circumferentially in SC except at regions of CC ostia where they assumed a radial configuration oriented toward the lumen of the CC. The area of microstent contact with SC external wall was examined with SEM and a comparison made between the 8 and 15 mm microstent showing a smaller area of indentation with the 8 mm microstent. The indentations were generally free of particulate debris, were smooth and were devoid of nuclear profiles. In bridged areas adjacent to areas of microstent contact, CCs were identified, appearing patent and intact like those of the control eyes. The eyes receiving 8 mm and 15 mm Hydrus microstents both maintained CC ostia patency but a smaller area of external wall contact was evident from insertion of the 8 mm microstent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomical Variation of Human Collector Channel Orifices

PURPOSE To examine the anatomical variation of normal human collector channel orifices and their relationship with Schlemm's canal. METHODS Ten human anterior segments fixed by immersion or perfusion were dissected radially and further divided by fine dissection into corresponding inner and outer wall segments. The tissues were dehydrated, critical-point dried, sputter coated, and examined by...

متن کامل

Musculature Associated with the Water Canals in Freshwater Mussels and Response to Monoamines In Vitro.

The gills of freshwater mussels perform many functions that depend on water flow through the water canals and channels. Regulation of water flow depends in part on ciliary activity and in part on the contraction of musculature underlying the gill filament and water channel epithelium. Obliquely striated muscles control water canal openings (ostia) at the base of the filaments and also at the en...

متن کامل

In Vivo Near-Infrared Fluorescence Imaging of Aqueous Humor Outflow Structures

The aim of this study has been to visualize the aqueous outflow system in patients affected by primary open angle glaucoma. A solution of indocyanine green (ICG) plus high viscosity viscoelastic solution was injected into the Schlemm canal during surgery in 10 glaucomatous patients undergoing canaloplasty. Soon after injection of the dye the borders of the scleral flap were completely stained d...

متن کامل

A novel Schlemm's Canal scaffold increases outflow facility in a human anterior segment perfusion model.

PURPOSE An intracanalicular scaffold (Hydrus microstent) designed to reduce intraocular pressure as a glaucoma treatment was tested in human anterior segments to determine changes in outflow facility (C). METHODS Human eyes with no history of ocular disease or surgeries were perfused within 49 hours of death. The anterior segments were isolated and connected to a perfusion system. Flow rates ...

متن کامل

Pressure in the canal of Schlemm.

THE pressure relationships in the anterior chamber, the canal of Schlemm, and the episcleral venous plexus are of obvious importance to the understanding of the drainage of aqueous humour. Episcleral venous pressures have been estimated by several workers (Thomassen, 1947 ; Linner, 1954 ; Bain, 1954), but so far no direct measurements of the pressure in the canal of Schlemm have been attempted....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental eye research

دوره 119  شماره 

صفحات  -

تاریخ انتشار 2014