A comparison of surface and fine wire EMG recordings of gluteus medius during selected maximum isometric voluntary contractions of the hip.
نویسندگان
چکیده
Electromyographic (EMG) studies into gluteus medius (GMed) typically involve surface EMG electrodes. Previous comparisons of surface and fine wire electrode recordings in other muscles during high load isometric tasks suggest that recordings between electrodes are comparable when the muscle is contracting at a high intensity, however, surface electrodes record additional activity when the muscle is contracting at a low intensity. The purpose of this study was to compare surface and fine wire recordings of GMed at high and low intensities of muscle contractions, under high load conditions (maximum voluntary isometric contractions, MVICs). Mann-Whitney U tests compared median electrode recordings during three MVIC hip actions; abduction, internal rotation and external rotation, in nine healthy adults. There were no significant differences between electrode recordings in positions that evoked a high intensity contraction (internal rotation and abduction, fine wire activity >77% MVIC; effect size, ES<0.42; p>0.277). During external rotation, the intensity of muscle activity was low (4.2% MVIC), and surface electrodes recorded additional myoelectric activity (ES=0.67, p=0.002). At low levels of muscle activity during high load isometric tasks, the use of surface electrodes may result in additional myoelectric recordings of GMed, potentially reflective of cross-talk from surrounding muscles.
منابع مشابه
Gluteus minimus: an intramuscular EMG investigation of anterior and posterior segments during gait.
Gluteus minimus is believed to consist of two structurally and functionally unique segments (anterior and posterior); however there is a lack of electromyography (EMG) research that attempts to verify current theoretical knowledge of this muscle. The purpose of this study was therefore to evaluate the function of gluteus minimus during gait, and to determine whether anterior and posterior segme...
متن کاملRehabilitation exercise progression for the gluteus medius muscle with consideration for iliopsoas tendinitis: an in vivo electromyography study.
BACKGROUND It is common for hip arthroscopy patients to demonstrate significant gluteus medius muscle weakness and concurrent iliopsoas tendinitis. Restoration of gluteus medius muscle function is essential for normal hip function. HYPOTHESIS A progression of hip rehabilitation exercises to strengthen the gluteus medius muscle could be identified that minimize concurrent iliopsoas muscle acti...
متن کاملHip Muscle Activity during Isometric Contraction of Hip Abduction
[Purpose] This study aimed to determine the effect of varying hip flexion angle on hip muscle activity during isometric contraction in abduction. [Subjects] Twenty-seven healthy men (mean age=21.5 years, SD=1.2) participated in this study. [Methods] Surface electromyography (EMG) was recorded of the upper portion of the gluteus maximus (UGM), lower portion of the gluteus maximus (LGM), tensor f...
متن کاملA comparison of two gluteus maximus EMG maximum voluntary isometric contraction positions
Background. The purpose of this study was to compare the peak electromyography (EMG) of the most commonly-used position in the literature, the prone bent-leg (90°) hip extension against manual resistance applied to the distal thigh (PRONE), to a novel position, the standing glute squeeze (SQUEEZE). Methods. Surface EMG electrodes were placed on the upper and lower gluteus maximus of thirteen re...
متن کاملComparing the Electromyography Activity of Core Muscles During Side Plank Exercise on Stable and Unstable Surfaces
Objective Numerous abdominal exercises with Swiss ball are used to improve core stability with strengthening and rehabilitation goals. It is claimed that the stability exercises have a greater impact on core muscle activation, but the validity of this claim is still in doubt. Moreover, there is no comprehensive study on the comparison of the core muscles activity in different core stability exe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
دوره 24 6 شماره
صفحات -
تاریخ انتشار 2014