Quantitative flow measurement by digital subtraction angiography in cerebral carotid stenosis using optical flow method.

نویسندگان

  • Tzung-Chi Huang
  • Tung-Hsin Wu
  • Yang-Hsien Lin
  • Wan-Yuo Guo
  • Wei-Chien Huang
  • Chung-Jung Lin
چکیده

OBJECTIVE We analyzed intracranial regional blood flows using an optical flow method (OFM) and digital subtraction angiography in patients with internal carotid artery (ICA) stenosis. We also retrospectively explored the correlation between the patients' diagnoses and the severity of the ICA stenoses. MATERIALS AND METHODS OFM, an image-processing algorithm to estimate motion, was applied to determine the mean velocity V(mean) in the vessels. A group of 40 patients without vascular anomalies acted as the control group. The patients were classified as having either moderate stenosis (< 80%, n=14) or severe stenosis (> 80%, n=23). RESULTS The V(mean) of the ICAs was significantly lower in the stenotic group compared with the control group (p< 0.01). The V(mean) of the ICAs was inversely correlated with the severity of the stenosis (p< 0.05). The receiver operating characteristic curve of the V(mean) in an AP view showed substantial discriminatory power, with an optimal cutoff value of 3.48 pixels/frame for the detection of patients with carotid stenosis. The sensitivity and specificity were 84% and 50%, respectively. On a lateral view, the best cutoff for the V(mean) was 4.01 pixels/frame, and the sensitivity and specificity were 92% and 43%, respectively. CONCLUSIONS Digital subtraction angiography combined with the OFM is a feasible parametric method for intracranial blood flow measurements in patients with moderate to severe carotid stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of extracranial carotid stenosis on intracranial blood flow.

BACKGROUND AND PURPOSE The hemodynamic effects of extracranial carotid stenosis on intracranial blood flow are not well characterized. We sought to determine the impact of degree of stenosis, stenosis length, and residual lumen on intracranial blood flow in patients with extracranial carotid stenosis. METHODS Carotid stenosis patients who had undergone both vessel flow rate measurements using...

متن کامل

Measurement of carotid stenosis using duplex ultrasonography with a microconvex array transducer: a validation with cerebral angiography.

BACKGROUND We aimed to evaluate the validity of duplex ultrasonography (DUS) using a microconvex array transducer (MAT) with enhanced flow imaging (EFI) for visualization of the distal, internal carotid artery (ICA) and the accurate assessment of ICA stenosis. METHODS Patients who underwent both DUS and digital subtraction angiography (DSA) were registered for this study. DUS was performed by...

متن کامل

Quantification of Blood Flow in Internal Cerebral Artery by Optical Flow Method on Digital Subtraction Angiography in Comparison with Time-Of-Flight Magnetic Resonance Angiography

OBJECTIVE This study compared data on the blood flow velocity in the internal carotid artery, which was obtained using the optical flow method (OFM) with digital subtraction angiography (DSA) and the time-of-flight (TOF) technique using magnetic resonance angiography (MRA). MATERIALS AND METHODS Images were obtained from 12 cerebrovascular patients who underwent both brain DSA and MRA imaging...

متن کامل

Comparison of extracranial artery stenosis and cerebral blood flow, assessed by quantitative magnetic resonance, using digital subtraction angiography as the reference standard

Extracranial arteriosclerosis usually indicates a high risk of ischemic stroke. In the past, a clinical decision following diagnosis was dependent on the percentage of vessel stenosis determined by an invasive technique. We aimed to develop a quantitative magnetic resonance (QMR) technique to evaluate artery structure and cerebral hemodynamics noninvasively.QMR and digital subtraction angiograp...

متن کامل

Computational fluid dynamics analysis of tandem carotid artery stenoses: Investigation of neurological complications after carotid artery stenting.

BACKGROUND Combined extra- and intracranial carotid artery stenoses, particularly involving multiple lesions, show complex hemodynamic properties and represent a therapeutic dilemma. We used computational fluid dynamics (CFD) to investigate whether insufficient cerebral blood flow (CBF) in a 70-year-old man with tandem stenoses was the cause of aphasia and right hemiparesis after carotid artery...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of X-ray science and technology

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2013