Time-invariant oxygen cost of mechanical energy in dog left ventricle: consistency and inconsistency of time-varying elastance model with myocardial energetics.

نویسندگان

  • Y Yasumura
  • T Nozawa
  • S Futaki
  • N Tanaka
  • H Suga
چکیده

We studied whether the oxygen cost of mechanical energy is time-invariant in the excised, cross-circulated canine heart. The total mechanical energy generated by ventricular contraction can be quantified by the total pressure-volume area (PVA) according to the time-varying elastance model. In this model, mechanical energy generated until a specified time (t) during systole can be quantified by the partial pressure-volume area, PVA(t). PVA(t) was obtained by quickly releasing ventricular volume at a varied time during isovolumic contraction. The quick release aborted further development of mechanical energy. We found that PVA(t) at a constant end-diastolic volume linearly correlated with myocardial oxygen consumption (VO2). This indicates that the oxygen cost of mechanical energy is time-invariant. However, we also found that the slope of the VO2-PVA(t) relation decreased with increasing quick-release speed. This indicates a decrease in VO2 by the quick release despite the same PVA(t). The time-invariant oxygen cost of mechanical energy is consistent with the time-varying elastance model of the ventricle, but the decreased VO2 with increasing quick-release speed despite the same PVA(t) is not.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-Invariant Oxygen Cost of Mechanical Energy in Dog Left Ventricle: Consistency and Inconsistency of Time-Varying Eiastance Model With Myocardial Energetics

We studied whether the oxygen cost of mechanical energy is time-invariant in the excised, cross-circulated canine heart. The total mechanical energy generated by ventricular contraction can be quantified by the total pressure-volume area (PVA) according to the time-varying eiastance model. In this model, mechanical energy generated until a specified time (t) during systole can be quantified by ...

متن کامل

Left ventricular time varying elastance behavior does not reflect a basic property of cardiac muscle.

The article of Hisano and Cooper raises once again the seemingly unresolved question on the myocardial basis for the time varying elastance behavior of the left ventricle, a concept formalized by Suga et al in 1973. From their experiments, Hisano and Cooper conclude that "the correlation of pressurevolume area with oxygen consumption on the ventricular level arises from a basic property of card...

متن کامل

Left ventricular function: time-varying elastance and left ventricular aortic coupling

Many aspects of left ventricular function are explained by considering ventricular pressure-volume characteristics. Contractility is best measured by the slope, Emax, of the end-systolic pressure-volume relationship. Ventricular systole is usefully characterized by a time-varying elastance (ΔP/ΔV). An extended area, the pressure-volume area, subtended by the ventricular pressure-volume loop (us...

متن کامل

Heat released during relaxation equals force-length area in isometric contractions of rabbit papillary muscle.

It has been claimed that the mechanical performance and the related energy turnover of the left ventricle can be reliably predicted on the basis of its time-varying elastance behavior. In its most elementary form, this behavior can be mathematically described by E(t) = P(t)/[V(t)-Vd], where E is ventricular elastance, t is time, P is ventricular pressure, V is ventricular volume, and Vd is the ...

متن کامل

Muscle Mechanics and Energetics: A Comparative View CARDIAC ENERGETICS: FROM E MAX TO PRESSURE–VOLUME AREA

1. To celebrate this Festschrift for Professor Colin Gibbs, as an invited speaker, I would like to review briefly my 35 year research career in cardiac physiology. 2. My career started in the late 1960s in Tokyo with my serendipitous discovery of E max (ventricular end-systolic maximum elastance) as a load-independent contractility index based on the time-varying elastance (E(t)) model of the v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 64 4  شماره 

صفحات  -

تاریخ انتشار 1989