Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials

نویسندگان

  • Ana Lucia MACHADO
  • Eunice Teresinha GIAMPAOLO
  • Carlos Eduardo VERGANI
  • Juliana Feltrin de SOUZA
  • Janaina Habib JORGE
چکیده

OBJECTIVE The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Trusoft-T; Sofreliner-S, Dentusil-D) was evaluated. MATERIAL AND METHODS Thirty specimens of each material were made and divided into 3 groups: Control - not disinfected; P - daily disinfection by immersing in sodium perborate solution (3.8%); MW - microwave disinfection (6 min/650 W). Roughness measurements were made after polymerization (baseline) and after 1, 3 and 28 days. Roughness differences relative to the baseline readings were analyzed by Student's t-test (P=0.05). RESULTS At baseline, Trusoft showed the highest (P<0.001) mean surface roughness (3.54 µm), and its surface roughness was significantly reduced after 28 days of disinfection by immersion in sodium perborate (P=0.013). Roughness measurements of material Trusoft were not performed after microwave disinfection due to the severe alterations on the surface. In the 3 groups evaluated, changes in roughness were significant for materials Ufi Gel hard (from 0.11 to 0.26 µm; P<0.041) and New Truliner (0.19 to 0.76 µm; P<0.019). The roughness of materials Lucitone 550 (0.37 µm), Tokuyama Rebase II (0.37 µm), Sofreliner (0.49 µm) and Dentusil (0.38 µm) remained unaffected (P>0.05). CONCLUSIONS The roughness of the hard reline materials Ufi Gel hard and New Truliner was adversely affected by microwave disinfection, immersion in water or in sodium perborate. Microwave disinfection caused severe alterations on the surface of the resilient liner Trusoft.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in roughness of denture base and reline irradiation. Surface roughness of denture base and reline materials

1Full Professor, Department of Dental Materials and Prosthodontics, Araraquara Dental School, UNESP Univ. Estadual Paulista , Araraquara, SP, Brazil. 2Associate Professor, Department of Dental Materials and Prosthodontics, Araraquara Dental School, UNESP Univ. Estadual Paulista, Araraquara, SP, Brazil. 3Former graduate student, Department of Dental Materials and Prosthodontics, Araraquara Denta...

متن کامل

Factors affecting the bond strength of denture base and reline acrylic resins to base metal materials

OBJECTIVE The shear bond strengths of two hard chairside reline resin materials and an auto-polymerizing denture base resin material to cast Ti and a Co-Cr alloy treated using four conditioning methods were investigated. MATERIAL AND METHODS Disk specimens (diameter 10 mm and thickness 2.5 mm) were cast from pure Ti and Co-Cr alloy. The specimens were wet-ground to a final surface finish of 6...

متن کامل

Dynamic mechanical properties of hard, direct denture reline resins.

STATEMENT OF PROBLEM Dynamic mechanical properties of hard, direct reline resins are important factors in the clinical success of dentures. However, little information is available on the nature of these properties. PURPOSE This study evaluated the dynamic mechanical properties of a variety of hard, direct reline resins: (1) visible light-polymerized, powder-liquid type, (2) visible light-pol...

متن کامل

بررسی تأثیر ضدعفونی کننده های شیمیایی بر خشونت سطحی آکریل بیس دنچر گرماپخت

Introduction & Objective: Chemical disinfectants should have minimum side effects on the denture base surface so they can reduce the amount of plaque accumulation. This study evaluates the effect of chemical disinfectants (glutaraldehyde 2% and sodium hypochlorite 1%, 2.5% and 5.25%) on surface roughness of heat cure acrylic denture. Materials & Methods: Fifty specimens were fabricated with...

متن کامل

Effect of microwave disinfection on denture base adaptation and resin surface roughness.

This study evaluated the effect of disinfection methods [chemical disinfection (immersion in 100 ppm chloride solution) or microwave disinfection (690 W for 6 min)] on the internal adaptation of denture bases and resin surface roughness. For the adaptation test, 18 maxillary denture bases were obtained from stone casts duplicated from a metallic master model and submitted to the following treat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2011