Precision grid and hand motion for accurate needle insertion in brachytherapy.
نویسندگان
چکیده
PURPOSE In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. METHODS The gauge repeatability and reproducibility (GR&R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2(3) factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. RESULTS Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. CONCLUSIONS In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.
منابع مشابه
Intraoperative factors associated with stranded source placement accuracy in low-dose-rate prostate brachytherapy.
PURPOSE The quality of a low-dose rate prostate brachytherapy implant depends on the accurate placement of sources in their planned locations. This study investigates intraoperative factors that potentially contribute to stranded source placement inaccuracy in prostate brachytherapy. METHODS AND MATERIALS Intraoperative video images of the brachytherapist's hand motions and needle insertions ...
متن کاملEffects of Rotational Motion in Robotic Needle Insertion
Background: Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations.Objective: In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploite...
متن کاملModeling and simulation of flexible needles.
Needle insertion is performed in many clinical and therapeutic procedures. Tissue displacement and needle bending which result from needle-tissue interaction make accurate targeting difficult. For performing physicians to gain essential needle targeting skills, needle insertion simulators can be used for training. An accurate needle bending model is essential for such simulators. These bending ...
متن کاملSensorless Motion Planning for Medical Needle Insertion in Deformable Tissue
Minimally invasive medical procedures such as biopsies, anesthesia drug injections, and brachytherapy cancer treatments require inserting a needle to a specific target inside soft tissue. This is difficult because needle insertion displaces and deforms the surrounding soft tissue causing the target to move during the procedure. To facilitate physician training and pre-operative planning for the...
متن کاملAutomated intraoperative calibration for prostate cancer brachytherapy.
PURPOSE Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called "calibration". The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. METHODS A device was CAD-designed and precision-engineered, which mechanically couples a cal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 38 8 شماره
صفحات -
تاریخ انتشار 2011