A statistical correction method for minimization of systemic artefact in a continuous-rotate X-ray based industrial CT system
نویسندگان
چکیده
The use of a linear detector array (LDA) in X-ray computed tomography (CT) imaging is well established. Generally the CT system using an LDA operates in a fan-beam configuration. In a non-medical tomography set-up, the X-ray source and detectors are stationary and the object is rotated for scanning. Equi-spaced angular projections over a complete 360 object rotation are required for CT image reconstruction using standard Convolution Back Projection (CBP) algorithm as applied to the fan-beam scanning geometry. If there is a lack of timing synchronization between the LDA data acquisition system and the rotary motion in a continuous-rotate system, the incremental angle for the acquired projections may not be known exactly. The error may cause artefacts and blurring in the CT image. The present paper describes a possible way of numerically tuning the acquired transmission data matrix for minimization of such artefacts. It is based on finding out statistically similar projections, which represent 0 and 360 angular views. The correction method has been developed to avoid modification in detector hardware and interface devices. The experimental CT system for industrial applications has been developed by making use of an independent scintillatorbased linear detector array, commonly used for on-line radiography of low-density specimens. The proposed data preprocessing algorithm with some experimental results as well as limitations of the correction method is discussed. r 2003 Elsevier B.V. All rights reserved. PACS: 87.59.Fm; 87.59.Jq; 87.59. e; 42.30.Wb; 07.85. m
منابع مشابه
Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملA Framework for Performance Assessment of Beam Hardening Correction Algorithms in Industrial Computed Tomography
Industrial computed tomography (CT) images often suffer from beam hardening (BH) artefacts. Since beam hardening correction (BHC) is crucial in industrial CT, it is worth acquiring a good understanding of the BHC algorithms. The purpose of this work concerns the development of a phantom-based framework to assess the performance of BHC algorithms in industrial CT, and its application on several ...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملStatistical analysis of Multi-Material Components using Dual Energy CT
This work describes a novel method for statistical analysis of multi-material components. The application scenario is industrial 3D X-ray computed tomography, emphasizing metrology of artefact affected plastics-metal components. The presented work makes use of dual energy CT data acquisition for artefact reduction, in order to optimize CT scans of multi-material components. Using statistical an...
متن کاملInvestigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کامل