An objective measure for selecting microphone modes in OMNI/DIR hearing aid circuits.
نویسندگان
چکیده
OBJECTIVES Studies have shown that listener preferences for omnidirectional (OMNI) or directional (DIR) processing in hearing aids depend largely on the characteristics of the listening environment, including the relative locations of the listener, signal sources, and noise sources; and whether reverberation is present. Many modern hearing aids incorporate algorithms to switch automatically between microphone modes based on an analysis of the acoustic environment. Little work has been done, however, to evaluate these devices with respect to user preferences, or to compare the outputs of different signal processing algorithms directly to make informed choices between the different microphone modes. This study describes a strategy for automatically switching between DIR and OMNI microphone modes based on a direct comparison between acoustic speech signals processed by DIR and OMNI algorithms in the same listening environment. In addition, data are shown regarding how a decision to choose one microphone mode over another might change as a function of speech to noise ratio (SNR) and spatial orientation of the listener. DESIGN Speech and noise signals were presented at a variety of SNR's and in different spatial orientations relative to a listener's head. Monaural recordings, made in both OMNI and DIR microphone processing modes, were analyzed using a model of auditory processing that highlights the spectral and temporal dynamics of speech. Differences between OMNI and DIR processing were expressed in terms of a modified spectrotemporal modulation index (mSTMI) developed specifically for this hearing aid application. Differences in mSTMI values were compared with intelligibility measures and user preference judgments made under the same listening conditions. RESULTS A comparison between the results of the mSTMI analyses and behavioral data (intelligibility and preference judgments) showed excellent agreement, especially in stationary noise backgrounds. In addition, the mSTMI was found to be sensitive to changes in SNR as well as spatial orientation of the listener relative to signal and noise sources. Subsequent mSTMI analyses on hearing aid recordings obtained from real-life environments with more than one talker and modulated noise backgrounds also showed promise for predicting the preferred microphone setting in varied and complex listening environments.
منابع مشابه
Influence of environmental factors on hearing aid microphone preference.
The purpose of this study was to identify characteristics of everyday listening situations that influence user preferences for omnidirectional versus directional hearing aid microphones. Eleven experienced hearing aid users were fitted with digital hearing aids featuring switchable omnidirectional (OMNI) and adaptive-directional (DIR) modes (programs). For 6 weeks, their task was to identify an...
متن کاملBenefit From Directional Microphone Hearing Aids: Objective and Subjective Evaluations
OBJECTIVES The aims of this study were to find and compare the effect of directional (DIR) processing of two different hearing aids via both subjective and objective methods, to determine the association between the results of the subjective and objective evaluations, and to find out individual predictive factors influencing the DIR benefit. METHODS Twenty-six hearing aid users fitted unilate...
متن کاملEvaluation of a "direct-comparison" approach to automatic switching in omnidirectional/directional hearing aids.
BACKGROUND Hearing aids today often provide both directional (DIR) and omnidirectional (OMNI) processing options with the currently active mode selected automatically by the device. The most common approach to automatic switching involves "acoustic scene analysis" where estimates of various acoustic properties of the listening environment (e.g., signal-to-noise ratio [SNR], overall sound level)...
متن کاملRelating hearing loss and executive functions to hearing aid users' preference for, and speech recognition with, different combinations of binaural noise reduction and microphone directionality
Knowledge of how executive functions relate to preferred hearing aid (HA) processing is sparse and seemingly inconsistent with related knowledge for speech recognition outcomes. This study thus aimed to find out if (1) performance on a measure of reading span (RS) is related to preferred binaural noise reduction (NR) strength, (2) similar relations exist for two different, non-verbal measures o...
متن کاملA MEMS Capacitive Microphone Modelling for Integrated Circuits
In this paper, a model for MEMS capacitive microphone is presented for integrated circuits. The microphone has a diaphragm thickness of 1 μm, 0.5 × 0.5 mm2 dimension, and an air gap of 1.0 μm. Using the analytical and simulation results, the important features of MEMS capacitive microphone such as pull-in voltage and sensitivity are obtained 3.8v and 6.916 mV/Pa, respectively while there is no...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ear and hearing
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2008