Differences in tests of aniseikonia.
نویسندگان
چکیده
The New Aniseikonia Test (NAT), a hand-held direct-comparison test using red/green anaglyphs, has several potential advantages as a screener. We compared the validity of the NAT to that of the Space Eikonometer in three experiments: (1) aniseikonia was induced by calibrated size lenses in a double-blind study of 15 normal subjects; (2) habitual aniseikonia was measured with both instruments in four patients; and (3) eight of the normal subjects were retested with a computer-video simulation of the NAT. The NAT underestimated induced aniseikonia by a factor of 3 in the normal subjects and underestimated habitual aniseikonia in four patients. The Space Eikonometer correctly measured the magnitude of induced aniseikonia in the normal subjects. The simulation test did not show underestimation in the eight normal subjects. We could not attribute the NAT's underestimation of aniseikonia to the red/green anaglyph method, printing error, psychophysical method, or the direct-comparison test format. We speculate that the NAT induces a different sensory fusion response to aniseikonia than do the other tests, and that this altered sensory fusion response diminishes measured aniseikonia. We conclude that the NAT is not a valid measure of aniseikonia.
منابع مشابه
Differences in Tests of Aniseikonio
The New Aniseikonia Test (NAT), a hand-held direct-comparison test using red/green anaglyphs, has several potential advantages as a screener. We compared the validity of the NAT to that of the Space Eikonometer in three experiments: (1) aniseikonia was induced by calibrated size lenses in a doubleblind study of 15 normal subjects; (2) habitual aniseikonia was measured with both instruments in f...
متن کاملThe evaluation of two new computer-based tests for measurement of Aniseikonia.
PURPOSE To evaluate the accuracy and repeatability of size lens induced aniseikonia measurement with the Aniseikonia Inspector Version 1 and a newer customized version of the Aniseikonia Inspector, Version 2. METHODS Aniseikonia was measured on 27 subjects with both versions of the Aniseikonia Inspector in normal room illumination. Measurements of induced aniseikonia were made using size lens...
متن کامل[A new method to quantify subjective aniseikonia].
PURPOSE To design subjective aniseikonia measuring criteria in order to quantify its value and to use it to the clinical practice. MATERIAL AND METHODS In order to carry out the aniseikonia measurements, a sinoptophore (Clement Clark) was used and two tests (one per eye of each patient) were performed. A viewfinder capable of measuring the difference in size between subjective images in both ...
متن کاملAniseikonia Tests: The Role of Viewing Mode, Response Bias, and Size-Color Illusions.
PURPOSE To identify the factors responsible for the poor validity of the most common aniseikonia tests, which involve size comparisons of red-green stimuli presented haploscopically. METHODS Aniseikonia was induced by afocal size lenses placed before one eye. Observers compared the sizes of semicircles presented haploscopically via color filters. The main factor under study was viewing mode (...
متن کاملNonoptical determinants of aniseikonia.
Interocular differences in apparent size (aniseikonia) are typically associated with interocular differences in refractive error (anisometropia). Aniseikonia is generally thought to reflect disparities in retinal image size that often accompany anisometropia. This assumption was examined with seven highly anisometropic subjects who were tested under conditions in which no substantial retinal im...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 33 6 شماره
صفحات -
تاریخ انتشار 1992