A Butyl Methacrylate Monolithic Column Prepared In-Situ on a Microfluidic Chip and its Applications
نویسندگان
چکیده
A butyl methacrylate (BMA) monolithic column was polymerized in-situ with UV irradiation in an ultraviolet transparent PDMS micro-channel on a homemade micro-fluidic chip. Under the optimized conditions and using a typical polymerization mixture consisting of 75% porogenic solvents and 25% monomers, the BMA monolithic column was obtained as expected. The BET surface area ratio of the BMA monolithic column was 366 m(2)·g(-1). The corresponding SEM images showed that the monolithic column material polymerized in a glass channel was composed of uniform pores and spherical particles with diameters ranging from 3 to 5 μm. The promethazine-luminal-potassium ferricyanide chemiluminescence system was selected for testing the capability of the column. A flow injection analytical technique-chemiluminescence (FIA-CL) system on the microfluidic chip with a BMA monolithic column pretreatment unit was established to determine promethazine. Trace promethazine was enriched by the BMA monolithic column, with more than a 10-fold average enrichment ratio. The proposed method has a linear response concentration range of 1.0×10(-8) - 1.0×10(-6)g·mL(-1) and the detection limit was 1.6×10(-9)g·mL(-1).
منابع مشابه
Monolithic porous polymer for on-chip solid-phase extraction and preconcentration prepared by photoinitiated in situ polymerization within a microfluidic device.
Monolithic porous polymers have been prepared by photoinitiated polymerization within the channels of a microfluidic device and used for on-chip solid-phase extraction and preconcentration. The preparation of the monolithic material with hydrophobic and ionizable surface chemistries is easily achieved by copolymerization of butyl methacrylate with ethylene dimethacrylate, or 2-hydroxyethyl meth...
متن کاملThermoplastic microfluidic device for on-chip purification of nucleic acids for disposable diagnostics.
A polymeric microfluidic device for solid-phase extraction (SPE)-based isolation of nucleic acids is demonstrated. The plastic chip can function as a disposable sample preparation system for different biological and diagnostic applications. The chip was fabricated in a cyclic polyolefin by hot-embossing with a master mold. The solid phase consisted of a porous monolithic polymer column impregna...
متن کاملLow-flow-resistance methacrylate-based polymer monolithic column prepared by low-conversion ultraviolet photopolymerization at low temperature.
A low-conversion poly(butyl methacrylate-co-ethylene dimethacrylate)-based polymer monolithic column was prepared by ultraviolet (UV) irradiation for a short time at a low temperature (-15°C). By UV irradiation for 2 min, the monolithic column exhibited a high permeability of 5.6 × 10(-13) m(2) and a high column efficiency of over 100000 plates m(-1). At this polymerization time, the conversi...
متن کاملOn-chip sample pretreatment using a porous polymer monolithic column for solid-phase microextraction and chemiluminescence determination of catechins in green tea.
A porous polymer monolithic column for solid-phase microextraction and chemiluminescence detection was integrated into a simple microfluidic chip for the extraction and determination of catechins in green tea. The porous polymer was prepared by poly(glycidyl methacrylate-co-ethylene dimethacrylate) and modified with ethylenediamine. Catechins can be concentrated in the porous polymer monolithic...
متن کاملMonolithic column with zwitterionic stationary phase for capillary electrochromatography.
A capillary electrochromatography (CEC) monolithic column with zwitterionic stationary phases was prepared by in situ polymerization of butyl methacrylate, ethylene dimethacrylate, methacrylic acid, and 2-(dimethyl amino) ethyl methacrylate in the presence of porogens. The stationary phases have zwitterionic functional groups, that is, both tertiary amine and acrylic acid groups, so the ionizat...
متن کامل