Reduced oxygen supply explains the negative force-frequency relation and the positive inotropic effect of adenosine in buffer-perfused hearts.

نویسندگان

  • Rodrigo M Marin
  • Kleber G Franchini
چکیده

In isolated rat hearts perfused with HEPES and red blood cell-enriched buffers, we examined changes in left ventricular pressure induced by increases in heart rate or infusion of adenosine to investigate whether the negative force-frequency relation and the positive inotropic effect of adenosine are related to an inadequate oxygen supply provided by crystalloid perfusates. Hearts perfused with HEPES buffer at a constant flow demonstrated a negative force-frequency relation, whereas hearts perfused with red blood cell-enriched buffer exhibited a positive force-frequency relation. In contrast, HEPES buffer-perfused hearts showed a concentration-dependent increase in left ventricular systolic pressure [EC50 = 7.0 +/- 1.2 nM, maximal effect (Emax) = 104 +/- 2 and 84 +/- 2 mmHg at 0.1 microM and baseline, respectively] in response to adenosine, whereas hearts perfused with red blood cell-enriched buffer showed no change in left ventricular pressure. The positive inotropic effect of adenosine correlated with the simultaneous reduction in heart rate (r = 0.67, P < 0.01; EC50 = 3.8 +/- 1.4 nM, baseline 228 +/- 21 beats/min to a minimum of 183 +/- 22 beats/min at 0.1 microM) and was abolished in isolated hearts paced to suppress the adenosine-induced bradycardia. In conclusion, these results indicate that the negative force-frequency relation and the positive inotropic effect of adenosine in the isolated rat heart are related to myocardial hypoxia, rather than functional peculiarities of the rat heart.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is rate–pressure product of any use in the isolated rat heart? Assessing cardiac ‘effort’ and oxygen consumption in the Langendorff‐perfused heart

NEW FINDINGS What is the central question of this study? Rate-pressure product (RPP) is commonly used as an index of cardiac 'effort'. In canine and human hearts (which have a positive force-frequency relationship), RPP is linearly correlated with oxygen consumption and has therefore been widely adopted as a species-independent index of cardiac work. However, given that isolated rodent hearts d...

متن کامل

Effect of imipramine and desipramine on adenosine receptors in isolated rat atria

  The effect of different doses (1-50 µ M) of imipramine (IMI) and desipramine (DES) on the rate and force of contraction of isolated rat atria was studied. IMI and DES produced a dose-dependent increase in force of contraction (31- 94% for IMI and 35-118% for DES). Pretreatment of rats with reserpine (5 mg/kg) on the isolated atria with propranolol (1 µ g) inhibited the positive ionotropic eff...

متن کامل

Effects of catecholamines, histamine, and nitroglycerin on flow, oxygen utilization, and adenosine production in the perfused guinea pig heart.

Adenosine release by the myocardium has been linked to a decrease in myocardial oxygen content and has been implicated in producing the concomitant increase in coronary flow. Epinephrine, norepinephrine, and histamine increase myocardial oxygen consumption and coronary flow. Nitroglycerin on the other hand, increases coronary flow but does not increase oxygen consumption. The purpose of the pre...

متن کامل

Xenon does not impair the responsiveness of cardiac muscle bundles to positive inotropic and chronotropic stimulation.

BACKGROUND Most volatile anesthetics exhibit a direct myocardial depressant effect. This side effect often limits their applicability in patients with impaired cardiac function. Xenon is a new gaseous anesthetic that did not show any adverse cardiovascular effects in clinical and experimental studies. The authors tested the hypothesis that xenon does not affect myocardial contractility or the p...

متن کامل

An improved isolated working rabbit heart preparation using red cell enhanced perfusate.

The performance of isolated working rabbit hearts perfused with Krebs-Henseleit (KH) buffer was compared with those in which the buffer was supplemented with washed human red blood cells (KH + RBC) at a hematocrit of 15 percent. When perfused with KH alone at 70 cm H2O afterload and paced at 240 beats/minute, coronary flow was more than double, whereas aortic flow was 40-60 percent of that in h...