Respiration signals from photoplethysmography.
نویسنده
چکیده
Pulse oximetry is based on the technique of photoplethysmography (PPG) wherein light transmitted through tissues is modulated by the pulse. In addition to variations in light modulation by the cardiac cycle, the PPG signal contains a respiratory modulation and variations associated with changing tissue blood volume of other origins. Cardiovascular, respiratory, and neural fluctuations in the PPG signal are of different frequencies and can all be characterized according to their sinusoidal components. PPG was described in 1937 to measure blood volume changes. The technique is today increasingly used, in part because of developments in semiconductor technology during recent decades that have resulted in considerable advances in PPG probe design. Artificial neural networks help to detect complex nonlinear relationships and are extensively used in electronic signal analysis, including PPG. Patient and/or probe-tissue movement artifacts are sources of signal interference. Physiologic variations such as vasoconstriction, a deep gasp, or yawn also affect the signal. Monitoring respiratory rates from PPG are often based on respiratory-induced intensity variations (RIIVs) contained in the baseline of the PPG signal. Qualitative RIIV signals may be used for monitoring purposes regardless of age, gender, anesthesia, and mode of ventilation. Detection of breaths in adult volunteers had a maximal error of 8%, and in infants the rates of overdetected and missed breaths using PPG were 1.5% and 2.7%, respectively. During central apnea, the rhythmic RIIV signals caused by variations in intrathoracic pressure disappear. PPG has been evaluated for detecting airway obstruction with a sensitivity of 75% and a specificity of 85%. The RIIV and the pulse synchronous PPG waveform are sensitive for detecting hypovolemia. The respiratory synchronous variation of the PPG pulse amplitude is an accurate predictor of fluid responsiveness. Pleth variability index is a continuous measure of the respiratory modulation of the pulse oximeter waveform and has been shown to predict fluid responsiveness in mechanically ventilated patients including infants. The pleth variability index value depends on the size of the tidal volume and on positive end-expiratory pressure. In conclusion, the respiration modulation of the PPG signal can be used to monitor respiratory rate. It is probable that improvements in neural network technology will increase sensitivity and specificity for detecting both central and obstructive apnea. The size of the PPG respiration variation can predict fluid responsiveness in mechanically ventilated patients.
منابع مشابه
Detection and Classification of Emotions Using Physiological Signals and Pattern Recognition Methods
Introduction: Emotions play an important role in health, communication, and interaction between humans. The ability to recognize the emotional status of people is an important indicator of health and natural relationships. In DEAP database, electroencephalogram (EEG) signals as well as environmental physiological signals related to 32 volunteers are registered. The participants in each video we...
متن کاملDetection and Classification of Emotions Using Physiological Signals and Pattern Recognition Methods
Introduction: Emotions play an important role in health, communication, and interaction between humans. The ability to recognize the emotional status of people is an important indicator of health and natural relationships. In DEAP database, electroencephalogram (EEG) signals as well as environmental physiological signals related to 32 volunteers are registered. The participants in each video we...
متن کاملCross Time-Frequency Analysis for Combining Information of Several Sources: Application to Estimation of Spontaneous Respiratory Rate from Photoplethysmography
A methodology that combines information from several nonstationary biological signals is presented. This methodology is based on time-frequency coherence, that quantifies the similarity of two signals in the time-frequency domain. A cross time-frequency analysis method, based on quadratic time-frequency distribution, has been used for combining information of several nonstationary biomedical si...
متن کاملAssessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration
Background: The importance of continuous monitoring along with rapid and accurate notification of changes in blood components such as hemoglobin concentration, especially in acute situations, encourages researchers to use non-invasive methods for measuring.Objective: This study was aimed to investigate the correlation between hemoglobin concentration and photoplethysmogram (PPG) and the p...
متن کاملMotion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise.
With the advance of computer and photonics technology, imaging photoplethysmography [(PPG), iPPG] can provide comfortable and comprehensive assessment over a wide range of anatomical locations. However, motion artifact is a major drawback in current iPPG systems, particularly in the context of clinical assessment. To overcome this issue, a new artifact-reduction method consisting of planar moti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 117 4 شماره
صفحات -
تاریخ انتشار 2013