Automation of Routine Microplate Pipetting and Dispensing

ثبت نشده
چکیده

Quantitative assays of all sorts are common to many applications in basic science and clinical research. Most of these assays require the movement, either addition or subtraction, of liquid reagents. Historically these assays were performed in test tubes. However, regardless of the assay method employed, laboratories requiring high throughput have often adapted the described protocol to a 96-well, and more recently, a 384-well format. Despite the adaptation, processing large numbers of samples generally represents a large investment in manpower, with automation primarily taking place at the endpoint of reading the plate. The standardized matrix and spacing of the wells in microplates, 8 x 12 and 16 x 24, for 96and 384-well microplates, respectively, has allowed the use of manual multichannel pipettes to pick up and dispense liquids when these microplates are employed. While these devices have certainly made pipetting fluids into these arrays much easier, they still require a high degree of manual manipulation. With today’s throughput requirements, this still represents a very tedious and time-consuming task. Towards that end, BioTek Instruments (Winooski, VT) has developed the Precision 2000 Automated Pipetting System to eliminate the need for manual pipetting into these plate formats. Although the performance of the Precision 2000 Automated Pipetting System has only been specified at volumes near 100 μl, its typical performance at much lower volumes is quite remarkable. In this monograph we will describe the dispense accuracy, linearity, and precision of the Precision 2000 at low volumes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Salmonella/microsome microsuspension assay with the new microplate fluctuation protocol for testing the mutagenicity of environmental samples.

The objective of this study was to compare the responses of the Salmonella/microsome microsuspension assay with the new microplate fluctuation protocol (MPF) for the evaluation of the mutagenic activity of environmental samples. Organic extracts of total particulate atmospheric air samples, surface waters, and effluents were tested in dose-response experiments. The assays were performed with st...

متن کامل

Magnetic, microplate-format plasmid isolation protocol for high-yield, sequencing-grade DNA.

We have developed a rapid, microplate-format plasmid isolation procedure to purify sequencing-grade DNA templates for high-throughput DNA sequencing operations. A modified lysozyme/boiling method is used to produce a plasmid-containing supernatant that is then purified by iron bead capture. After binding, the beads are pelleted in a magnetic field, washed and the DNA eluted in water. The method...

متن کامل

· Technical note Design of a PLC system for automatic I-123 production

 ABSTRACTBackground: Design of the production system for Iodine-123 has begun recently in nuclear research centre of agricultural and medicine (NRCAM). The production system consists of pipes for xenon gas transfer, equipped with 10 valves, 3 heaters, fluid nitrogen and 2 vacuum pumps. In the first prototype the function of elements was being done manually by an operator. Because dispensing rad...

متن کامل

Semiautomatic Determination of Serum Glucose and Urea Using a New Three-channel Pipetting Machine.

T’ HE ECONOMICAL MANAGEMENT of a hospital laboratory requires the gradual replacement of manual by mechanical manipulations. Fully automatic devices are now available for serial determinations on blood arid other biologic fluids, but their use is sometimes limited by financial and space considerations, even to the big laboratories performing some hundred or more analyses of the same type every ...

متن کامل

Time-motion analysis of 6 cystic fibrosis mutation detection systems.

BACKGROUND A dramatic increase in requests for routine cystic fibrosis (CF) carrier screening prompted us to conduct a time-motion analysis comparing commercially available CF testing platforms. Questions addressed in the study included: (a) How much time is required to perform each step involved in carrying out the assay procedure? (b) Which system requires the minimum number of manual manipul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006