A non-invasive, on-line deuterium dilution technique for the measurement of total body water in haemodialysis patients.

نویسندگان

  • Cian Chan
  • David Smith
  • Patrik Spanel
  • Christopher W McIntyre
  • Simon J Davies
چکیده

BACKGROUND Despite its importance, total body water (TBW) is usually estimated rather than measured due to the complexity of isotope dilution methods. The aim of this study was to demonstrate the applicability in haemodialysis (HD) patients of a recently developed on-line breath test, previously validated in healthy subjects, that uses the gold standard deuterium dilution method to measure TBW. In particular we wished to show that a pre-dialysis estimation was as good as a post-dialysis equilibrated measurement in order to avoid patients needing to remain behind after dialysis treatment. METHODS The dispersal kinetics of breath HDO, measured using a flowing afterglow mass spectrometer (FA-MS) following ingestion of D(2)O immediately post-dialysis, were determined in 12 haemodialysis patients and used to calculate the absolute TBW(PostHD) after full equilibration. TBW(PreHD) was then determined from breath samples taken immediately prior to the next dialysis. This measurement was adjusted for the interdialytic weight change and urine output (TBW(PreHD-adjusted)) and compared to the TBW(PostHD). The accuracy and precision of FA-MS was also assessed using known concentrations of deuterium-enriched water samples. RESULTS Mean TBW(PostHD) was 50.0 +/- 9.3 L and TBW(PreHD-adjusted) was 50.7 +/- 9.0 L. They were highly correlated (R = 0.99, P < 0.001) with a CV of 2.6%. The mean difference was +0.74 L (SEM 0.35, 95% CI -0.03 to 1.51 L, P = 0.059), compatible with a daily insensible loss of 0.37 L. Accuracy and precision of FA-MS were comparable to the previous validation work. CONCLUSIONS This non-invasive adaptation of the D isotope dilution method for determining TBW can be applied to haemodialysis patients who show deuterium equilibration kinetics identical to normal subjects; a pre-dialysis estimation may be used to determine TBW, and so avoiding the necessity to remain behind after dialysis making this suitable for application in the clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isotope dilution spaces of mice injected simultaneously with deuterium, tritium and oxygen-18.

The isotope dilution technique for measuring total body water (TBW), and the doubly labelled water (DLW) method for measuring energy expenditure, are both sensitive to small variations in the ratio of the hydrogen to oxygen-18 dilution space. Since the dilution space ratio varies between individuals, there has been much recent debate over what causes this variability (i.e. physiological differe...

متن کامل

The Volume of Distribution of Sodium Thiosulfate

The importance of total body fluid and electrolytes and their distribution in the body cell mass has been increasingly emphasized in the care of acutely and chronically ill patients. In order to determine distribution of water and electrolytes, a convenient and accurate technique for the estimation of the extracellular fluid space is essential. Moore (1) has demonstrated that the chemical disse...

متن کامل

Four-component model of body composition in chronic renal failure comprising dual-energy X-ray absorptiometry and measurement of total body water by deuterium oxide dilution.

1. Assessment of nutrition in patients with chronic renal failure by body composition measurement techniques may be affected by variable hydration. 2. This study aimed to derive a four-component model of body composition (consisting of fat, protein, total body water and body mineral) from a combination of dual-energy X-ray absorptiometry and total body water measured by deuterium oxide dilution...

متن کامل

Volaemic assessment of the elderly hyponatraemic patient: reliability of clinical assessment and validation of bioelectrical impedance analysis.

BACKGROUND Hyponatraemia is the commonest electrolyte disturbance of hospital inpatients. Assessment of volaemic status is an important part of diagnosis and management. AIM To determine reliability of clinical assessment of volaemic state by assessing inter-observer variability of clinical measures of volaemic state. To assess validity of bioelectrical impedance analysis as a tool to measure...

متن کامل

Body Composition of Bangladeshi Children: Comparison and Development of Leg-to-Leg Bioelectrical Impedance Equation

The aim of this study was to investigate the validity of the Tanita TBF 300A leg-to-leg bioimpedance analyzer for estimating fat-free mass (FFM) in Bangladeshi children aged 4-10 years and to develop novel prediction equations for use in this population, using deuterium dilution as the reference method. Two hundred Bangladeshi children were enrolled. The isotope dilution technique with deuteriu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2008