The effect of measurement error on the test-retest reliability of repeated mismatch negativity measurements.
نویسندگان
چکیده
OBJECTIVE The aim was to study how the measurement error affects the repeatability of mismatch negativity (MMN) measurements. METHODS Event-related potentials (ERPs) to changes in sound frequency, location, intensity, duration, and composition were recorded five times during 1-3 weeks from 13 healthy adults using a multi-feature MMN paradigm. The accumulation of MMN was modeled empirically with respect to measurement error, and repeatability was estimated at 0.6-3.5-μV error levels. The analysis was made for the results in the single deviant conditions and their pattern (auditory discrimination profile). RESULTS At the single-subject level, the measurement error significantly affected the repeatability until it went below 9-17% of MMN peak amplitude. At the group level, the threshold was higher. Peak amplitude was generally the most repeatable parameter. Latency was superior when the error was moderate or small (<2-3 μV). CONCLUSIONS The measurement error affects the repeatability of MMN. In single-subject studies, it should not be neglected if it exceeds 10% of the MMN amplitude. The application of the auditory discrimination profile is recommended for future applications. SIGNIFICANCE The study provided quantitative results to support the discussion on improving the repeatability of the MMN measurements. They are expected to apply conditionally to other ERP measurements, too.
منابع مشابه
Test-Retest Reliability of Dynamic Postural Stability Measures in Healthy and Chronic Non-specific Low Back Pain Groups
Objective: The primary aim of the present study was to study the reliability of postural stability measures during whole body dynamic conditions, so they can be used in postural stability evaluations, investigations of injury mechanisms and assessments of treatment efficacy. Materials & Methods: Twelve healthy volunteers and 12 low back pain patients performed repeated trunk bending motions ...
متن کاملStatistical methods for assessing measurement error (reliability) in variables relevant to sports medicine.
Minimal measurement error (reliability) during the collection of interval- and ratio-type data is critically important to sports medicine research. The main components of measurement error are systematic bias (e.g. general learning or fatigue effects on the tests) and random error due to biological or mechanical variation. Both error components should be meaningfully quantified for the sports p...
متن کاملTest-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects
Abstract Background: Postural instability has been identified as a potential precursor of falls in elderly subjects. Postural stability in quiet stance is commonly assessed with center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure (COP) measures in the elderly subjects. Met...
متن کاملA mobile recording system and an acquisition control method for average event-related potential measurements
Aalto University, P.O. Box 11000, FI-00076 Aalto www.aalto.fi Author Antti Paukkunen Name of the doctoral dissertation A mobile recording system and an acquisition control method for average event-related potential measurements Publisher School of Electrical Engineering Unit Department of Electronics Series Aalto University publication series DOCTORAL DISSERTATIONS 35/2012 Field of research App...
متن کاملTest-Retest Reliability of a Pendant-Worn Sensor Device in Measuring Chair Rise Performance in Older Persons
Chair rise performance is incorporated in clinical assessments to indicate fall risk status in older persons. This study investigated the test-retest reliability of a pendant-sensor-based assessment of chair rise performance. Forty-one older persons (28 females, 13 males, age: 72-94) were assessed in two sessions with 3 to 8 days in between. Repeated chair rise transfers were measured after dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
دوره 122 11 شماره
صفحات -
تاریخ انتشار 2011