Predictors of loss of atrioventricular synchrony in single lead VDD pacing.

نویسندگان

  • P Hunziker
  • P Buser
  • M Pfisterer
  • F Burkart
  • S Osswald
چکیده

OBJECTIVE To evaluate maintenance of proper VDD function, defined as persistence of sinus rhythm with atrial synchronous ventricular pacing, and to define factors predicting failure of the VDD mode in patients with atrioventricular (AV) block and normal sinus function. DESIGN Observational study in 86 consecutive patients (mean (SD) age 74 (12) years; 38 women, 48 men) with single lead VDD pacing systems (Intermedics Unity, n = 66, Medtronic Thera VDD, n = 20), implanted for high degree AV block with documented normal sinus node. Pacemaker function was assessed by event counters, telemetric measurements, and Holter recordings. Demographic, radiological, and pacing variables were correlated with loss of proper VDD function. RESULTS During a mean (SD) follow up of 10 (10) months (range 1-37), sinus rhythm and atrial triggered ventricular pacing were maintained in 70 of 86 patients (81%). Atrial undersensing was observed in nine patients, lead migration in two, atrial fibrillation in three, and symptomatic sinus bradycardia in two. Univariate predictors of loss of proper VDD function were: low position of the atrial dipole relative to the carina (> or = 6 cm; p < 0.01) during fluoroscopy; and maximum programmable atrial sensitivity of the pacemaker (p = 0.03). In a multivariate analysis, only dipole position remained predictive of outcome (p < 0.02). Not predictive were sex, age, symptoms before pacemaker implantation, cardiothoracic ratio or dilatation of individual heart chambers on chest x ray, side of device implant, and P wave amplitude at implant. CONCLUSIONS To maintain proper VDD function in the long term, a low anatomical dipole position relative to the carina should be avoided. Electrical guidance of dipole positioning does not seem to influence long term outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stable Atrial Sensing on Long-Term Follow Up of VDD Pacemakers

BACKGROUND The hemodynamic advantages of maintaining AV synchrony through AV synchronous pacing are widely known as compared to single chamber pacing. DDD pacemaker implantation entails higher cost and is technically more challenging than the VDD pacemaker. METHODS Seventy one patients underwent VDD lead (Biotronik GmbH, St. Jude Medical and Medtronic Inc.) implantation at KEM hospital, Mumba...

متن کامل

Immediate and mid-term safety and efficacy of single lead VDD pacemakers for patients with atrioventricular block and normal sinus node function--a single centre experience.

INTRODUCTION Single lead atrial synchronous ventricular pacing (VDD) is increasingly being used in place of conventional dual chamber pacing (DDD) for patients with atrioventricular block and preserved sinus node function. Compared to the latter, VDD pacemakers provide similar haemodynamic benefits derived from atrial synchronous pacing, with the added benefit of an easier implant procedure. ...

متن کامل

Dual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker?

BACKGROUND Dual chamber pacemakers (single chamber pacing dual chamber sensing cardiac pacemaker (VDD) and dual chamber pacing and sensing cardiac pacemaker (DDD)) are being used frequently in children and adolescents. The aim of this study was to verify the safety and performance of the VDD and DDD pacing systems, and to evaluate the differences between two pacing modes with regard to atrial s...

متن کامل

[Safety and effectiveness of single-lead VDD pacing].

INTRODUCTION AND OBJECTIVES Single-lead VDD pacing provides the physiological benefits of atrioventricular synchrony with the convenience of a single-lead system. However, concern remains about the method's safety and effectiveness. METHOD In total, 700 patients with single-lead VDD pacemakers were evaluated retrospectively. The following parameters were recorded: age, sex, etiology, the symp...

متن کامل

Cost-effectiveness of dual-chamber pacemaker therapy: does single lead VDD pacing reduce treatment costs of atrioventricular block?

AIMS Implantation of single-lead VDD pacemakers is an established alternative to DDD pacing in patients with atrioventricular block. This study compares the long-term costs of both systems. METHODS AND RESULTS Three hundred and sixty patients with atrioventricular block received VDD or DDD pacemakers in alternating order. Primary costs of implantation included: devices, leads and operation ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 80 4  شماره 

صفحات  -

تاریخ انتشار 1998