Estimation of effective lens position using a method independent of preoperative keratometry readings.

نویسندگان

  • Ian Dooley
  • Sofia Charalampidou
  • John Nolan
  • James Loughman
  • Laura Molloy
  • Stephen Beatty
چکیده

PURPOSE To evaluate the validity of a keratometry (K)-independent method of estimating effective lens position (ELP) before phacoemulsification cataract surgery. SETTING Institute of Eye Surgery, Whitfield Clinic, Waterford, Ireland. DESIGN Evaluation of diagnostic test or technology. METHODS The anterior chamber diameter and corneal height in eyes scheduled for cataract surgery were measured with a rotating Scheimpflug camera. Corneal height and anterior chamber diameter were used to estimate the ELP in a K-independent method (using the SRK/T [ELP(rs)] and Holladay 1 [ELP(rh)] formulas). RESULTS The mean ELP was calculated using the traditional (mean ELP(s) 5.59 mm ± 0.52 mm [SD]; mean ELP(h) 5.63 ± 0.42 mm) and K-independent (mean ELP(rs) 5.55 ± 0.42 mm; mean ELP(rh) ± SD 5.60 ± 0.36 mm) methods. Agreement between ELP(s) and ELP(rs) and between ELP(h) and ELP(rh) were represented by Bland-Altman plots, with mean differences (± 1.96 SD) of 0.06 ± 0.65 mm (range -0.59 to +0.71 mm; P=.08) in association with ELP(rs) and -0.04 ± 0.39 mm (range -0.43 to +0.35 mm; P=.08) in association with ELP(rh). The mean absolute error for ELP(s) versus ELP(rs) estimation and for ELP(h) versus ELP(rh) estimation was 0.242 ± 0.222 mm (range 0.001 to 1.272 mm) and 0.152 ± 0.137 mm (range 0.001 to 0.814 mm), respectively. CONCLUSION This study confirms that the K-independent ELP estimation method is comparable to traditional K-dependent methods and may be useful in post-refractive surgery patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Simultaneous Phacoemulsification and Graft Refractive Surgery in Penetrating Keratoplasty Eyes

Purpose. To report outcomes of graft refractive surgery (GRS) along with clear-cornea phacoemulsification and intraocular lens (IOL) implantation in penetrating keratoplasty (PKP) eyes. Methods. Fourteen eyes of 13 patients who had received PKP underwent simultaneous GRS (relaxing incisions with or without counter-quadrant compression sutures) and clear-cornea phacoemulsification with IOL impla...

متن کامل

[Intraocular lens power calculation after corneal photorefractive surgery. Literature review].

OBJECTIVE Revision of methods for estimating corneal power (Kpost) and effective lens position (ELP) for cataract surgery after corneal refractive surgery. METHODS Review of medical literature. RESULTS To calculate the intraocular lens that achieves emetropia after corneal refractive surgery it is necessary to correct the Kpost and to estimate the effective lens position again correcting it...

متن کامل

IOLMaster versus Manual Keratometry after Photorefractive Keratectomy

PURPOSE To compare keratometric measurements using a Javal type manual keratometer with IOLMaster in eyes undergoing photorefractive keratectomy (PRK) for myopia. METHODS In this comparative case series, we studied patients aged 21 to 27 years scheduled for myopic PRK. Keratometry was performed preoperatively and three months after the procedure using a Javal type manual keratometer and the I...

متن کامل

Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power

PURPOSE To determine whether the total corneal refractive power (TCRP) value, which is based on measurement of both anterior and posterior corneal astigmatism, is effective for toric intraocular lens (IOL) calculation with AcrySof(®) Toric IOLs. PATIENTS AND METHODS A consecutive series of cataract surgery cases with AcrySof toric IOL implantation was studied retrospectively. The IOLMaster(®)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2011