Plasticizers in blood--real or artifactual?

نویسندگان

  • T Maxwell
  • G W Milne
  • H M Fales
  • N Law
چکیده

During our recent work on the identification of drugs involved in overdose cases (1, 2), we have had occasion to investigate the constituents found in blood, urine, and gastric juices by combined GC-mass spectrometry. In a surprisingly large number of cases, we have observed, in addition to any drugs present, one or more peaks corresponding to phthalate esters (PAEs). Most commonly these were di-n-butyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP), but occasionally di-2-ethylhexyl adipate and butyl cellosolve phosphate were also present. Often they were present at remarkably high levels, e.g., 200 mg/100 ml in blood. In view of the many possible sources of these plasticizers in the hospital and laboratory environment, we deemed it advisable to study in more detail blood samples from normal individuals, taking special care to prevent the introduction of such compounds from outside sources during sample workup.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood Bag Plasticizers Influence Red Blood Cell Vesiculation Rate without Altering the Lipid Composition of the Vesicles.

BACKGROUND Polyvinyl chloride (PVC) plasticized with di(2-ethylhexyl) phthalate (DEHP) is commonly used for blood collection and storage. DEHP has protective effects on RBC membranes, but is also a toxin. METHODS A paired study was conducted to investigate the influence of DEHP and two alternative plasticizers, 1,2-cyclohexane-dicarboxylic acid diisononyl ester (DINCH) and n-butyryl-tri-n-hex...

متن کامل

The value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]

Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...

متن کامل

Artifactual hypoglycemia: an old term for a new classification.

The American Diabetes Association and The Endocrine Society workgroup on the 2013 classification of hypoglycemia (1) in patients with diabetes changed the previously used term “relative hypoglycemia” to “pseudo-hypoglycemia”while defining symptoms of hypoglycemia without confirmatory low glucose values and failing to include falsely low readings of glucose on capillary blood samples (1,2). In t...

متن کامل

Distribution of di(2-ethylhexyl) phthalate and products in blood and blood components.

In order to impart flexibility, plastic medical devices incorporate liquid plasticizers into their structure. Data from several laboratories, including ours, have shown that these compounds leach from blood bags and tubing during collection of blood, storage of various blood components and during kidney dialysis and cell and plasma apheresis procedures. After the plasticizer di(2-ethylhexyl) ph...

متن کامل

What Is Their Significance?

According to Webster,1 the terms “spurious,” “artifactual,” or “pseudo” denote false or deceptive resemblance. These terms when used specifically to hypertension refer to something that does not correspond with reality—a false perception; implicit in this definition is normalcy or a benign prognosis. Before discussion of the pros and cons of spurious, artifactual, or pseudohypertension, one sho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 3  شماره 

صفحات  -

تاریخ انتشار 1973