Prevalence of American Heart Association type VI carotid atherosclerotic lesions identified by magnetic resonance imaging for different levels of stenosis as measured by duplex ultrasound.

نویسندگان

  • Tobias Saam
  • Hunter R Underhill
  • Baocheng Chu
  • Norihide Takaya
  • Jianming Cai
  • Nayak L Polissar
  • Chun Yuan
  • Thomas S Hatsukami
چکیده

OBJECTIVES Via magnetic resonance imaging (MRI), we sought to determine the prevalence of atherosclerotic American Heart Association type VI lesions (AHA-LT6) (lesions with luminal surface defect, hemorrhage/thrombus, or calcified nodule) in carotid arteries that represented all categories of stenosis as measured by duplex ultrasound. BACKGROUND Arterial stenosis alone has been shown to be a poor predictor of cardiovascular events. Autopsy studies suggest that features associated with AHA-LT6 lesions, rather than the degree of luminal narrowing, characterize the high-risk plaque. METHODS A total of 192 subjects underwent bilateral carotid artery magnetic resonance imaging (MRI) scans at 1.5T after evaluation with ultrasound to determine stenosis. After excluding arteries with a previous endarterectomy, poor image quality, or missing ultrasound data, there were 175 patients with 260 arteries available for analysis. The AHA lesion type was determined by the consensus opinion of 2 experienced carotid MRI reviewers. RESULTS In total, 96 of 260 (37.0%) arteries had >or=1 location with AHA-LT6. Of the arteries with AHA-LT6, 84.4% had hemorrhage, 45.8% had a ruptured fibrous cap, and 14.6% showed other type of complications. Prevalence of AHA-LT6 was an increasing sequence of 8.1% in the 37 arteries with 1% to 15% stenosis, 21.7% in the 60 arteries with 16% to 49% stenosis, 36.8% in the 114 arteries with 50% to 79% stenosis, and 77.6% in the 49 arteries with 80% to 99% stenosis. CONCLUSIONS Complicated AHA-LT6 are frequently found in arteries with <or=50% stenosis. These findings indicate that complex lesions develop in a substantial number of arteries in the absence of high-grade stenosis. Ongoing prospective studies will determine the predictive value of vulnerable plaque features, as visualized by MRI, for risk of subsequent ischemic events.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atherosclerotic carotid vulnerable plaque and subsequent stroke: a high-resolution MRI study.

BACKGROUND High-resolution contrast-enhanced magnetic resonance imaging (CEMRI) has been proven to be an effective tool for the identification of carotid atherosclerotic vulnerable plaque, such as a large lipid core and thin fibrous cap. The aim of this study was to evaluate the relationship between carotid plaque characteristics and the types of stroke in patients who had carotid artery (CA) s...

متن کامل

Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging.

BACKGROUND Recent studies demonstrated that in vivo and ex vivo MRI can characterize the components of the carotid atherosclerotic plaque, such as fibrous tissue, lipid/necrotic core, calcium, hemorrhage, and thrombus. The purpose of this study was to determine whether in vivo high-resolution multicontrast MRI could accurately classify human carotid atherosclerotic plaque according to the Ameri...

متن کامل

Comparison of symptomatic and asymptomatic atherosclerotic carotid plaques using parallel imaging and 3 T black-blood in vivo CMR

BACKGROUND To determine if black-blood 3 T cardiovascular magnetic resonance (bb-CMR) can depict differences between symptomatic and asymptomatic carotid atherosclerotic plaques in acute ischemic stroke patients. METHODS In this prospective monocentric observational study 34 patients (24 males; 70 ±9.3 years) with symptomatic carotid disease defined as ischemic brain lesions in one internal c...

متن کامل

Reader and platform reproducibility for quantitative assessment of carotid atherosclerotic plaque using 1.5T Siemens, Philips, and General Electric scanners.

PURPOSE To evaluate the platform and reader reproducibility of quantitative carotid plaque measurements. MATERIALS AND METHODS A total of 32 individuals with >or=15% carotid stenosis by duplex ultrasound were each imaged once by a 1.5T General Electric (GE) whole body scanner and twice by either a 1.5T Philips scanner or a 1.5T Siemens scanner. A standardized multisequence protocol and identi...

متن کامل

Magnetic resonance imaging of carotid atherosclerotic plaque in clinically suspected acute transient ischemic attack and acute ischemic stroke.

BACKGROUND Carotid atherosclerotic plaque rupture is thought to cause transient ischemic attack (TIA) and ischemic stroke (IS). Pathological hallmarks of these plaques have been identified through observational studies. Although generally accepted, the relationship between cerebral thromboembolism and in situ atherosclerotic plaque morphology has never been directly observed noninvasively in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 51 10  شماره 

صفحات  -

تاریخ انتشار 2008