A histometric comparison of smooth and rough titanium implants in human low-density jawbone.

نویسندگان

  • P Trisi
  • W Rao
  • A Rebaudi
چکیده

The aim of this investigation was to conduct a comparative histometric analysis of bone-implant interface between a rough titanium surface and smooth implants in low-density human jawbone after 3, 6, and 12 months of submerged, undisturbed healing. Six adult volunteer patients undergoing standard implant placement were enrolled in this project. Each patient received 1 smooth and 1 rough implant. After 3, 6, and 12 months, the implants were harvested for histometric analysis. The values of bone-implant contact were the following: 3 months smooth 6.2%, 3 months rough 58.9%, 6 months smooth 3.55%, 6 months rough 72.9%, 12 months smooth 6.7%, and 12 months rough 76.75%. The results showed that in low-density bone the rough surface dramatically enhanced the amount of bone-to-implant contact. Because of the small number of implants examined, definite conclusions cannot be drawn, even though the statistical analysis showed significant differences between the smooth and rough groups (P = .0129; F = 76.065). Nevertheless, a trend was evident in these observations: while a rough implant surface may enhance the rate of osseointegration, it is not able to significantly change the bone density, and an implant placed low-density bone is at a higher risk of failure when occlusal loading begins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible.

BACKGROUND Today, implants are placed using both non-submerged and submerged approaches, and in 1- and 2-piece configurations. Previous work has demonstrated that peri-implant crestal bone reactions differ radiographically under such conditions and are dependent on a rough/smooth implant border in 1-piece implants and on the location of the interface (microgap) between the implant and abutment/...

متن کامل

Crestal bone changes around titanium implants: a methodologic study comparing linear radiographic with histometric measurements.

Generally, endosseous implants can be placed according to a nonsubmerged or a submerged technique and in 1-piece or 2-piece configurations. Recently, it has been shown that peri-implant crestal bone reactions differ significantly radiographically as well as histometrically under such conditions and are dependent on a rough/smooth implant border in 1-piece implants and on the location of a micro...

متن کامل

Argon-based atmospheric pressure plasma enhances early bone response to rough titanium surfaces.

This study investigated the effect of an Argon-based atmospheric pressure plasma (APP) surface treatment operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: rough titanium surface (Ti) and rough titanium surface + Argon-based APP (Ti-Plasma). Surface energy was characterized by the Owens-...

متن کامل

The response of human osteoblasts, epithelial cells, fibroblasts, macrophages and oral bacteria to nanostructured titanium surfaces: a systematic study

Nanotopography modification is a major focus of interest in current titanium surface design; however, the influence of the nanostructured surface on human cell/bacterium behavior has rarely been systematically evaluated. In this study, a homogeneous nanofiber structure was prepared on a titanium surface (Nano) by alkali-hydrothermal treatment, and the effects of this Nano surface on the behavio...

متن کامل

Bone density around titanium implants may be influenced by intermittent cigarette smoke inhalation: a histometric study in rats.

PURPOSE This study investigated the influence of cigarette smoke on bone healing around titanium implants placed in rats. MATERIALS AND METHODS After administration of anesthesia, the tibia surface was exposed and screw-shaped titanium implants (4.0 mm in length and 2.2 mm in diameter) were placed bilaterally (1 each side). The animals (n = 32) were randomly assigned to either group 1 (contro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 14 5  شماره 

صفحات  -

تاریخ انتشار 1999