Comparison of the Reliability of Anatomic Landmarks based on PA Cephalometric Radiographs and 3D CT Scans in Patients with Facial Asymmetry

نویسندگان

  • Kamal Bajaj
  • Pooja Rathee
  • Pradeep Jain
  • Vasim Raja Panwar
چکیده

INTRODUCTION Conventional cephalometry is an inexpensive and well-established method for evaluating patients with dentofacial deformities. However, patients with major deformities and in particular asymmetric cases are difficult to evaluate by conventional cephalometry. Reliable and accurate evaluation in the orbital and midfacial region in craniofacial syndrome patients is difficult due to inherent geometric magnification, distortion and the superpositioning of the craniofacial structures on cephalograms. Both two- and three-dimensional computed tomography (CT) have been proposed to alleviate some of these difficulties. AIMS AND OBJECTIVES The aim of our study is to compare the reliability of anatomic cephalometric points obtained from the two modalities: Conventional posteroanterior cephalograms and 3D CT of patients with facial asymmetry, by comparison of intra- and interobserver variation of points recorded from frontal X-ray to those recorded from 3D CT. MATERIALS AND METHODS The sample included nine patients (5 males and 4 females) with an age range of 14 to 21 years and a mean age of 17.11 years, whose treatment plan called for correction of facial asymmetry. All CT scans were measured twice by two investigators with 2 weeks separation for determination of intraobserver and interobserver variability. Similarly, all measurement points on the frontal cephalograms were traced twice with 2 weeks separation. The tracings were superimposed and the average distance between replicate points readings were used as a measure of intra- and interobserver reliability. Intra-and interobserver variations are calculated for each method and the data were imported directly into the statistical program, SPSS 10.0.1 for windows. RESULTS Intraobserver variations of points defined on 3D CT were small compared with frontal cephalograms. The intraobserver variations ranged from 0 (A1, B1) to 0.6 mm with the variations less than 0.5 mm for most of the points. Interobserver variations of points between first and second tracings defined on PA Ceph and 3D CT were less than 1.5 mm for all the points. A direct comparison of frontal cephalometry and 3D CT using intraobserver variation for the first observer showed that 3D CT was more reliable than frontal cephalometry for 11 points. Direct comparison of frontal cephalometry and 3D CT for the second observer showed a similar tendency with 14 points significantly more reliable for 3D CT. Comparison of frontal cephalometry and 3D CT using interobserver variation for the tracings showed that 3D CT was more reliable than frontal cephalometry. SUMMARY AND CONCLUSION The study has shown that 3D CT is consistently more accurate and reliable than conventional frontal cephalometry. Unfortunately, the cost of a computerized tomography examination is considerable; this means that, at this stage, its use by surgeons and orthodontists is a last resort.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of frontal radiographs obtained from cone beam CT scans and conventional frontal radiographs of human skulls.

This study evaluated whether measurements on conventional frontal radiographs are comparable with measurements on cone beam computed tomography (CBCT)-constructed frontal cephalometric radiographs taken from dry human skulls. CBCT scans and conventional frontal cephalometric radiographs were made of 40 dry skulls. With I-Cat Vision((R)) software, a cephalometric radiograph was constructed from ...

متن کامل

A comparison between 2D and 3D cephalometry on CBCT scans of human skulls.

The purpose of this study was to evaluate whether measurements on conventional cephalometric radiographs are comparable with 3D measurements on 3D models of human skulls, derived from cone beam CT (CBCT) data. A CBCT scan and a conventional cephalometric radiograph were made of 40 dry skulls. Standard cephalometric software was used to identify landmarks on both the 2D images and the 3D models....

متن کامل

Comparison of the Reliability of Anatomic Landmarks based on PA Cephalometric Radiographs

1Kamal Bajaj, 2Pooja Rathee, 3Pradeep Jain, 4Vasim Raja Panwar 1Reader, Department of Orthodontics, Rajasthan Dental College, Jaipur, Rajasthan, India 2Assistant Professor, Department of Orthodontics, Government Dental College, Jaipur, Rajasthan, India 3Professor and Head, Department of Orthodontics, Government Dental College, Jaipur, Rajasthan, India 4Clinical Assistant, Department of Orthodon...

متن کامل

Comparison of observer reliability of three-dimensional cephalometric landmark identification on subject images from Galileos and i-CAT cone beam CT.

OBJECTIVES Recently, there has been increasing interest in the use of cone beam CT (CBCT) for three-dimensional cephalometric analysis and craniofacial reconstruction in orthodontic and orthognathic surgical treatment planning. However, there is a need to redefine the cephalometric landmarks in three dimensional cephalometric analysis and to demonstrate the reproducibility of landmark identific...

متن کامل

Comparison of cephalometric radiographs obtained from cone-beam computed tomography scans and conventional radiographs.

PURPOSE We evaluated whether measurements on conventional cephalometric radiographs are comparable to measurements on cone-beam computed tomography (CBCT)-constructed cephalometric radiographs taken from human skulls. MATERIALS AND METHODS The CBCT scans and conventional cephalometric radiographs were made using 40 dry skulls. With I-Cat Vision software (Imaging Sciences International, Inc, H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2011