Discriminating among degenerative parkinsonisms using advanced 123I-ioflupane SPECT analyses

نویسندگان

  • Simon Badoud
  • Dimitri Van De Ville
  • Nicolas Nicastro
  • Valentina Garibotto
  • Pierre R. Burkhard
  • Sven Haller
چکیده

(123)I-ioflupane single photon emission computed tomography (SPECT) is a sensitive and well established imaging tool in Parkinson's disease (PD) and atypical parkinsonian syndromes (APS), yet a discrimination between PD and APS has been considered inconsistent at least based on visual inspection or simple region of interest analyses. We here reappraise this issue by applying advanced image analysis techniques to separate PD from the various APS. This study included 392 consecutive patients with degenerative parkinsonism undergoing (123)I-ioflupane SPECT at our institution over the last decade: 306 PD, 24 multiple system atrophy (MSA), 32 progressive supranuclear palsy (PSP) and 30 corticobasal degeneration (CBD) patients. Data analysis included voxel-wise univariate statistical parametric mapping and multivariate pattern recognition using linear discriminant classifiers. MSA and PSP showed less ioflupane uptake in the head of caudate nucleus relative to PD and CBD, yet there was no difference between MSA and PSP. CBD had higher uptake in both putamen relative to PD, MSA and PSP. Classification was significant for PD versus APS (AUC 0.69, p < 0.05) and between APS subtypes (MSA vs CBD AUC 0.80, p < 0.05; MSA vs PSP AUC 0.69 p < 0.05; CBD vs PSP AUC 0.69 p < 0.05). Both striatal and extra-striatal regions contain classification information, yet the combination of both regions does not significantly improve classification accuracy. PD, MSA, PSP and CBD have distinct patterns of dopaminergic depletion on (123)I-ioflupane SPECT. The high specificity of 84-90% for PD versus APS indicates that the classifier is particularly useful for confirming APS cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database

Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...

متن کامل

123I-ioflupane brain SPECT and 123I-MIBG cardiac planar scintigraphy combined use in uncertain parkinsonian disorders

We evaluated the clinical usefulness of the combined use of I-ioflupane brain single photon emission computed tomography (SPECT) and I-metaiodobenzylguanidine (MIBG) cardiac scintigraphy in discriminating uncertain parkinsonism with vascular lesions in striatal nuclei at magnetic resonance imaging (MRI). Forty-three consecutive patients with uncertain parkinsonism and vascular lesions at MRI in...

متن کامل

123I-ioflupane SPECT scan in a patient with Creutzfeldt-Jakob disease.

A 62-year-old woman presented with gait ataxia, bradykinesia, bilateral rigidity, choreic and dystonic movements, and psychomotor slowing. Magnetic resonance imaging (MRI) (Fig. 1), EEG and CSF analysis were compatible with a diagnosis of Creutzfeldt-Jakob disease (CJD). The 123I-ioflupane SPECT (Fig. 2) was normal, indicating the relative sparing of nigro-striatal fibers and suggesting that he...

متن کامل

Accumulation of 123I-Ioflupane Is a Useful Marker of the Efficacy of Selegiline Monotherapy in Drug-Naïve Parkinson’s Disease

Background: Selegiline enhances the patient's endogenous dopamine by inhibiting dopamine metabolism. The efficacy of selegiline monotherapy for drug-naïve Parkinson's disease (PD) patients may depend on the degree of dopaminergic neuronal degeneration. 123I-Ioflupane single photon emission computed tomography (SPECT) and 123I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy are diagnosti...

متن کامل

Clinical utility of dopamine transporter single photon emission CT (DaT-SPECT) with (123I) ioflupane in diagnosis of parkinsonian syndromes

The diagnosis of movement disorders including Parkinson's disease (PD) and essential tremor is determined through clinical assessment. The difficulty with diagnosis of early PD has been highlighted in several recent clinical trials. Studies have suggested relatively high clinical diagnostic error rates for PD and essential tremor. This review was undertaken to clarify the utility of DaT-SPECT i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -