Role and Responsibilities of Laboratory Medicine Specialists in the Verification OF Metrological Traceability of in vitro Medical Diagnostics
نویسندگان
چکیده
To be accurate and equivalent, laboratory results should be traceable to higher-order references. Furthermore, their quality should fulfill acceptable measurement uncertainty as defined to fit the intended clinical use. With this aim, in vitro diagnostics (IVD) manufacturers should define a calibration hierarchy to assign traceable values to their system calibrators and to fulfill during this process uncertainty limits for calibrators, which should represent a proportion of the uncertainty budget allowed for clinical laboratory results. It is therefore important that, on one hand, the laboratory profession clearly defines the clinically acceptable uncertainty for relevant tests and, on the other hand, end-users may know and verify how manufacturers have implemented the traceability of their calibrators and estimated the corresponding uncertainty. Important tools for IVD traceability surveillance are quality control programmes through the daily verification by clinical laboratories that control materials of analytical systems are in the manufacturer's declared validation range [Internal Quality Control (IQC) component I] and the organization of External Quality Assessment Schemes meeting metrological criteria. In a separate way, clinical laboratories should also monitor the reliability of employed commercial systems through the IQC component II, devoted to estimation of the measurement uncertainty due to random effects, which includes analytical system imprecision together with individual laboratory performance in terms of variability.
منابع مشابه
Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies.
To be accurate and equivalent, laboratory results should be traceable to higher-order references. Furthermore, their analytical performance should fulfill acceptable measurement uncertainty criteria defined to fit the intended clinical use. With this aim, In Vitro Diagnostics (IVD) manufacturers should define a calibration hierarchy to assign traceable values to their system calibrators and to ...
متن کاملProtective Role of Hypothermia Against Heat Stress in Differentiated and Undifferentiated Human Neural Precursor Cells: A Differential Approach for the Treatment of Traumatic Brain Injury
Introduction: The present study aimed to explore protective mechanisms of hypothermia against mild cold and heat stress on highly proliferative homogeneous human Neural Precursor Cells (NPCs) derived from Subventricular Zone (SVZ) of human fetal brain. Methods: CD133+ve enriched undifferentiated and differentiated human NPCs were exposed to heat stress at 42°C. Then, Western-blot qua...
متن کاملPerformance criteria for combined uncertainty budget in the implementation of metrological traceability.
The measurement uncertainty budget should combine the uncertainty of higher order references, the uncertainty of commercial system calibration, the system imprecision and individual laboratory performance in terms of variability. Here we recommend that no more than one third of the total uncertainty budget, established by appropriate analytical performance specifications, is consumed by the unc...
متن کاملPanteghini Performance criteria for combined uncertainty budget in the implementation of metrological traceability
The measurement uncertainty budget should combine the uncertainty of higher order references, the uncertainty of commercial system calibration, the system imprecision and individual laboratory performance in terms of variability. Here we recommend that no more than one third of the total uncertainty budget, established by appropriate analytical performance specifications, is consumed by the unc...
متن کاملPanteghini Performance criteria for combined uncertainty budget in the implementation of metrological
The measurement uncertainty budget should combine the uncertainty of higher order references, the uncertainty of commercial system calibration, the system imprecision and individual laboratory performance in terms of variability. Here we recommend that no more than one third of the total uncertainty budget, established by appropriate analytical performance specifications, is consumed by the unc...
متن کامل