The Importance of the 240 nm Absorbance Measurement
ثبت نشده
چکیده
The assessment of nucleic acid purity by the A260/A280 ratio has been used for a number of years. This measurement, however, does not provide all the information that investigator needs to assess nucleic acid preparations. The detection of impurities common to nucleic acid preparations that are not detected with absorbance measurements at 260 nm and 280 nm can in most instances be accomplished by measuring absorbance at 240 nm. Here we describe the use of the BioTek Instruments PowerWave 200TM scanning microplate spectrophotometer to measure nucleic acid preparations at 240 nm in conjunction with the traditional A260/A280 ratio to detect contaminants.
منابع مشابه
Decrease time, increase throughput in prion and amyloid seeding assays
* Limit of detection < 100 amol of biotinylated and phosphorylated polypeptide (P-Tyr-100 assay kit, PerkinElmer, #6760620C), measured in white 384 small volume microplates (17 μL/well) Limit of detection was calculated according to the IUPAC standard: 3x(SDblank)/slope ©2016 All rights reserved. All logos and trademarks are the property of BMG LABTECH. Detection Modes Fluorescence Intensity in...
متن کاملMeasurement of Scattering and Absorption Cross Sections of Microspheres for Wavelengths between 240 nm and 800 nm
A commercial spectrometer with a 150 mm integrating sphere (IS) detector was used to estimate the scattering and absorption cross sections of monodisperse polystyrene microspheres suspended in water. Absorbance measurements were performed with the sample placed inside the IS detector. The styrene absorption was non zero for wavelengths less than 300 nm. Correction for fluorescence emission by s...
متن کاملSpectrophotometric and Chromatographic Determination of Acetylsalicylic Acid and Caffeine in Pure and in Tablet Dosage Form
In the present research paper, spectrophotometric and chromatographic assay method has been developed for the simultaneous estimation of acetylsalicylic acid and caffeine in bulk and commercial tablets. Acetylsalicylic acid and caffeine showed absorbance maxima at 228 and 275 nm in 0.1N HCl and at 225 and 272 nm in methanol, respectively. These drugs were estimated in formulations by simultaneo...
متن کاملSPECTROPHOTOMETRIC REACTION RATE METHOD FOR THE DETERMINATION OF NITRITE BY CATALYTIC ACTION ON NILE BLUE A BROMATE REACTION
A kinetic method developed for the determination of ultra-trace amounts of nitrite based on its catalytic effect on the reaction between potassium bromate and Nile blue A in strongly acidic media is reported. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of Nile blue A at 645 nm by the fixed-time method. The decrease in absorbance during the first...
متن کاملUV absorbance of the human cornea in the 240- to 400-nm range.
PURPOSE To determine the UV absorbance of the corneal layers (epithelium, Bowman layer, stroma) in the 240- to 400-nm range. METHODS Consecutive slices (100 microm) of human cadaveric corneas were cut, and the UV absorbance of each sample was determined in a scanning spectrophotometer. In some cases the epithelium was scraped off and its absorbance measured separately. RESULTS The investiga...
متن کامل