Contemporary Ceramic Total Hip Arthroplasty in Patients with Cerebral Palsy: Does It Work?
نویسندگان
چکیده
BACKGROUND Adult patients with cerebral palsy (CP), who have advanced degenerative arthritis of the hip, have been treated with resection arthroplasty and arthrodesis. Although total hip arthroplasty (THA) has also been used as one of the alternative options, there are few studies on contemporary bearings used in THA. Therefore, we evaluated the results of the contemporary ceramic-on-ceramic THA in adult patients with CP. METHODS From January 2005 to December 2007, five adult CP patients (5 hips) underwent THA using contemporary ceramic-on-ceramic bearings. All patients were able to stand or ambulate with intermittent use of assistive devices at home. We retrospectively reviewed the series to determine the results of THA in terms of pain relief, improved function, and durability of prosthesis. RESULTS There were 3 men and 2 women with a mean age of 35.9 years. All patients had pain relief without decline in mobility postoperatively. One hip was dislocated, which was treated successfully with closed reduction and an abduction brace for 2 months. There was no ceramic fracture, loosening, or osteolysis during the mean follow-up of 6.8 years (range, 5.8 to 8.3 years). CONCLUSIONS Cementless THA using contemporary ceramic-on-ceramic bearings is a useful option for the treatment of advanced degenerative arthritis of the hip in ambulatory adults with CP.
منابع مشابه
Ceramic-on-ceramic total hip arthroplasty in patients younger than 20 years.
Total hip arthroplasty (THA) in the adolescent patient has historically shown relatively poor survivorship. This study reports the results of THA in young patients using contemporary ceramic bearings. Twenty-four THAs were performed using ceramic bearing surfaces in patients 20 years old or younger (mean, 16.4; range, 12-20). Average follow-up was 52 months (range, 25-123 months). The survival ...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملConstrained total hip arthroplasty in a paediatric patient with cerebral palsy and painful dislocation of the hip. A case report.
We describe a patient with cerebral palsy, of normal intelligence, who could not walk but who by the age of 16 had been successfully managed with a staged bilateral total hip arthroplasty using a constrained liner.
متن کاملCeramic liner fractures presenting as squeaking after primary total hip arthroplasty.
BACKGROUND Squeaking after ceramic-on-ceramic total hip arthroplasty is a relatively uncommon phenomenon. It usually does not require treatment in the absence of pain, mechanical symptoms, and/or relentless squeaking. The purpose of this investigation was to report on four patients who presented with hip pain and squeaking due to fractured ceramic liners after ceramic-on-ceramic total hip arthr...
متن کاملFracture of ceramic components as a serious failure after total hip replacement with ceramic-on-ceramic bearings
Introduction Ceramics have been introduced in total hip arthroplasty for several advantages including minimal friction, low wear, biocompatibility, no ageing problems and no problems related to the systemic increases in serum metal concentrations. In the first generation of ceramic components introduced in the 1970’s the risk of fracture was substantial, reaching up to 13.4 %. After introducing...
متن کامل