Novel Charge Sensitive Amplifier Design Methodology suitable for Large Detector Capacitance Applications
نویسندگان
چکیده
Current mode charge sensitive amplifier (CSA) topology and related methodology for use as pre-amplification block in radiation detection read out front end IC systems is proposed1. It is based on the use of a suitably configured current conveyor topology providing advantageous noise performance characteristics in comparison to the typical used CSA structures. In the proposed architecture the noise at the output of the CSA is independent of the detector capacitance value, allowing the use of large area detectors without affecting the system noise performance. Theoretical analysis and simulation analysis are performed concerning the operation – performance of the proposed topology. Measurement results on a current mode CSA prototype fabricated with a 0.35 m CMOS process by μ Austriamicrosystems are provided supporting the theoretical and simulation results and confirming the performance mainly in terms of the noise performance dependency on the detector capacitance value.
منابع مشابه
Low cost front-end readout electronic for instrumentation used in neutron experiments
In the field of material characterization, the neutron scattering technique is found to be useful in so many applications. This technique requires a position sensitive neutron detector (PSND) and their frontend readouts (FER) electronic to detect the position of neutron interactions. Normally, the PSND is designed for specific applications and has unique technical specifications. Therefore, it ...
متن کاملVortextm – a New High Performance Silicon Drift Detector for Xrd and Xrf Applications
A new class of silicon drift detectors (SDD), called “VortexTM”, with a large active area (~ 0.5 cm), high-energy resolution (<150 eV FWHM) and high-count rate capability (>1 Mcps) has been developed for X-ray diffraction (XRD) and X-ray fluorescence (XRF) applications. The VortexTM design allows for a relatively large active area while still maintaining a very low anode capacitance (~ 60 fF). ...
متن کاملFront-End Electronics for a TPC-Detector
The CERES/NA45-Collaboration upgrades the existing lepton-pair spectrometer at the CERN SPS with a TPC detector which improves the momentum resolution. We present the development of new front-end electronics to read out the nearly 20000 channels of the chamber. It is comprised of two circuits: (i) A continuously sensitive preamplifier with semi-Gaussian shaper and tailcancellation, which offers...
متن کاملA VLSI Implementation of High Sensitive Fingerprint Sensor using Parasitic Insensitive Charge Transfer Circuit
This paper implements 80x64 array high sensitive fingerprint sensor with the parasitic insensitive charge transfer circuit. The fingerprint sensor cell uses an active output voltage feedback integrator. The parasitic insensitive charge transfer circuit includes a differential amplifier and two switches to remove parasitic capacitance and transfer charge. The operation is validated by HSPICE for...
متن کاملCharge transformer to enhance noise performance of single-electron transistor amplifiers in high-capacitance applications
Following the discovery of Coulomb blockade phenomena arising from discreteness of charge and the advances in nanofabrication techniques, we have been able to make new kinds of devices that enable us to control and measure the motion of a single electron. One of the most exciting examples of such a device is a single electron transistor ~SET! which is an extremely precise solid-state electromet...
متن کامل