Mechanical and thermal properties of polyamide versus reinforced PMMA denture base materials

نویسندگان

  • Koray Soygun
  • Giray Bolayir
  • Ali Boztug
چکیده

PURPOSE This in vitro study intended to investigate the mechanical and thermal characteristics of Valplast, and of polymethyl methacrylate denture base resin in which different esthetic fibers (E-glass, nylon 6 or nylon 6.6) were added. MATERIALS AND METHODS FIVE GROUPS WERE FORMED: control (PMMA), PMMA-E glass, PMMA-nylon 6, PMMA-nylon 6.6 and Valplast resin. For the transverse strength test the specimens were prepared in accordance with ANSI/ADA specification No.12, and for the impact test ASTM D-256 standard were used. With the intent to evaluate the properties of transverse strength, the three-point bending (n=7) test instrument (Lloyd NK5, Lloyd Instruments Ltd, Fareham Hampshire, UK) was used at 5 mm/min. A Dynatup 9250 HV (Instron, UK) device was employed for the impact strength (n=7). All of the resin samples were tested by using thermo-mechanical analysis (Shimadzu TMA 50, Shimadzu, Japan). The data were analyzed by Kruskal-Wallis and Tukey tests for pairwise comparisons of the groups at the 0.05 level of significance. RESULTS IN ALL MECHANICAL TESTS, THE HIGHEST VALUES WERE OBSERVED IN VALPLAST GROUP (TRANSVERSE STRENGTH: 117.22 ± 37.80 MPa, maximum deflection: 27.55 ± 1.48 mm, impact strength: 0.76 ± 0.03 kN). Upon examining the thermo-mechanical analysis data, it was seen that the E value of the control sample was 8.08 MPa, higher than that of the all other samples. CONCLUSION Although Valplast denture material has good mechanical strength, its elastic modulus is not high enough to meet the standard of PMMA materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shear Bond Strength of Acrylic Denture Teeth to PMMA and Polyamide Denture Base Materials

Introduction: Detachment of denture teeth from denture base is one of the most common reasons for costly denture repairs .This study aimed at evaluating the bond strength of an acrylic denture tooth to polyamide injection-molded thermoplastic denture base material compared with three conventional polymethylmethacrylate (PMMA) denture base resins. Materials and Method: A total of 40 acrylic dent...

متن کامل

Polyamides As A Denture Base Material – A Review

The dentists today have to meet growing demands for prosthetic rehabilitation due to population aging and higher requirements on the quality of life. That means higher demands on the functional reliability of dental appliances, their aesthetical and biological properties. Several studies have evaluated various properties of polyamide (nylon) denture base materials. According to the results of t...

متن کامل

Polyamide as a Denture Base Material: A Literature Review

The purpose of this article was to review the biocompatibility, physical, and mechanical properties of the polyamide denture base materials. An electronic search of scientific papers from 1990-2014 was carried out using PubMed, Scopus and Wiley Inter Science engines using the search terms "nylon denture base" and "polyamide denture base". Searching the key words yielded a total of 82 articles. ...

متن کامل

Effect of different amounts of 3-methacryloxypropyltrimethoxysilane

Recently, there have been many materials used for denture base such as polymethyl methacrylate (PMMA) resin, modifi ed PMMA resin and nylon1,2). The material most often used to fabricate denture base and denture teeth was PMMA resin. PMMA is the most commonly used material due to its good mechanical and physical properties, compatibility with oral tissue, aesthetics, ease of repair and low cost...

متن کامل

Evaluating surface roughness of a polyamide denture base material in comparison with poly (methyl methacrylate).

Polyamide denture base materials are more flexible than the commonly used poly (methyl methacrylate) (PMMA). However polishability of polyamides has not been examined adequately. This study investigated the surface roughness (Ra) and clinical acceptability of samples of a polyamide denture base material and PMMA fabricated by injection moulding and traditional heat processing systems, respectiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2013