The photoplethysmographic amplitude to pulse pressure ratio can track sudden changes in vascular compliance and resistance during liver graft reperfusion
نویسندگان
چکیده
During liver transplantation, the thermodilution cardiac output (CO) technique cannot respond to sudden hemodynamic changes associated with postreperfusion syndrome. Photoplethysmography (PPG) can reflect changes in intravascular volume and thus can be used to assess vasomotor tone and arterial stiffness on the pressure-volume relation. We investigated whether a beat-to-beat analysis of the arterial pressure-PPG relationship can estimate dynamic changes in vascular characteristics immediately after liver graft reperfusion.In 10 recipients, arterial blood pressure and PPG waveforms recorded simultaneously were analyzed from the beginning of fall to nadir in systolic blood pressure immediately after reperfusion. On a beat-to-beat basis, we compared the ratio of the amplitude of PPG to arterial pulse pressure (PPGamp/PP, as relative vascular compliance) to total peripheral resistance (TPR) and Windkessel compliance (Cwk) obtained from the Modelflow CO algorithm.Following graft reperfusion, PPGamp/PP and Cwk increased (median 41.5%; P = .005 and 42.0%; P < .001, respectively), whereas TPR decreased (median -46.4%; P < .001). Beat-to-beat PPGamp/PP was negatively correlated with TPR (median r = -0.80 [95% CI -0.85 to -0.76] on linear regression and r = 0.84 [95% CI 0.73-0.92] on curvilinear regression), and was positively correlated with Cwk (median r = 0.86 [95% CI 0.81-0.91] on linear regression and r = 0.88 [95% CI 0.75-0.96] on curvilinear regression).Our results suggest that relative compliance, obtained from beat-to-beat analysis of PPG and arterial pressure waveforms, can track abrupt changes in vascular characteristics associated with postreperfusion syndrome. This simple index would contribute to differential diagnoses of sudden hypotension.
منابع مشابه
Arterial Blood Oxygen Saturation during Blood Pressure Cuff-induced Hypoperfusion
Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vaso...
متن کاملDoes Heart Affect Peripheral Vascular Resistance Following Myocardial Ischemia and Reperfusion?
Objective(s) The aim of this study was to investigate the overall effect of cardiac vasoactive factors during coronary occlusion and reperfusion on peripheral vascular tone, using a sequential isolated rabbit heart-ear perfusion model. Materials and Methods Isolated ears were perfused with the effluent of isolated hearts subjected to ischemia (30 min) and reperfusion (180 min, n=6). The comp...
متن کاملGraft reperfusion of transplanted liver–perfect storm for coronary vasospasm
Major adverse cardiac events in patients during liver transplantation are due to preexisting cardiopulmonary comorbidities and the impact of surgery on hemodynamics. Graft reperfusion of the transplanted liver is the most hemodynamically critical phase and can be associated with air embolism and the release of acidotic, cold, hyperkalemic effluent containing vaso-constrictive chemical mediators...
متن کاملPilot investigation of photoplethysmographic signals and blood oxygen saturation values during blood pressure cuff-induced hypoperfusion
Photoplethysmography (PPG) is a non-invasive electro-optical technique widely used in the monitoring of the pulsations associated with changes in blood volume in a peripheral vascular bed. The technique is based on the absorption properties of vascular tissue when it is transilluminated by light. Photoplethysmography is also used in the estimation of arterial blood oxygen saturation ðSpO2Þ by p...
متن کاملPulse wave reflection: can it explain the differences between systemic and pulmonary pressure and flow waves? A study in dogs.
We have studied the effect of changes in pulse wave reflection on the configurations of pressure and flow in systemic and pulmonary circulation. Electromagnetic flow transducers, atrial catheters, and pacing leads were implanted in 10 dogs. In four animals, the flow transducer was placed on the pulmonary artery, in another four on the ascending aorta, and in two additional dogs on both vessels....
متن کامل