Bispectral index is related to the spread of spinal sensory block in patients with combined spinal and general anaesthesia.

نویسندگان

  • R Iida
  • K Iwasaki
  • J Kato
  • S Ogawa
چکیده

BACKGROUND A relationship between the depth of sedation as measured by the bispectral index (BIS) and spinal sensory block height in patients with light to no additional sedation has been described previously. The present study was designed to investigate the hypothesis that BIS values closely correlate with the spread of spinal sensory block in patients deeply sedated with an i.v. target-controlled infusion of propofol. METHODS Subjects comprised 100 patients aged 20-64 yr and undergoing arthroscopic knee surgery. Patients were given spinal anaesthesia with bupivacaine 0.5% (3 ml). Propofol was administered to achieve a target effect-site concentration of 3.0 μg ml⁻¹. The relationship between the spinal sensory level at 15 min after spinal anaesthesia and BIS values during 1-5, 6-10, 11-15, and 16-20 min time intervals after the estimated effect-site concentration reached 3.0 μg ml⁻¹ was evaluated. RESULTS The sensory level of spinal analgesia significantly and strongly correlated with BIS values during each time period after the estimated effect-site concentration remained at 3.0 μg ml⁻¹ (P<0.0001). The correlation coefficient values were 0.8 during 1-5 min, 0.844 during 6-10 min, 0.801 during 11-15 min, and 0.804 during 16-20 min time periods. CONCLUSIONS We demonstrated that BIS values significantly correlate with the level of spinal sensory block under deep sedation with propofol. The depth of sedation induced by spinal anaesthesia depends on the spread of spinal sensory block.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Spinal Anesthesia in L3-L4 and L4-L5 on Sensory-Motor Block Level and Hemodynamic Status in Cesarean Section

Background and Objective: The injection site in spinal anesthesia is one of the factors that can affect the height of the sensory block. This clinical trial study aimed to compare the effect of spinal anesthesia at L3-L4 and L4-L5 on the level of sensory-motor block and hemodynamic status in cesarean section. Materials and Methods: Seventy patients undergoing elective cesarean section and rece...

متن کامل

مقایسه‌ی اثر بلوک حس‍ی- حرکت‍ی بوپیواکائین با لیدوکائین دوز پایین و هیپرباریک در جراح‍ی آنورکتال به روش بی‌حس‍ی نخاع‍ی

Background & Objective: Outpatient surgery can be performed by general or spinal anesthesia. Spinal anesthetic drugs have side effects. Many anesthesiologists choose general anesthesia, because of its relative predictability and to avoid undesirable side effects associated with spinal anesthesia. For example lidocaine is frequently associated with Transient Neuroligic Symptoms (TNS). Bupivacain...

متن کامل

بررسی اثرات افزودن فنتانیل به بوپیواکائین در بی‌حسی نخاعی بیماران وابسته به تریاک

Introduction: Spinal anesthesia in opium-addicted patients can be associated with many complications. Hence, this study aimed to investigate sensory and motor block characteristics, duration of postoperative analgesia, hemodynamic and side effects by adding Fentanyl to bupivacaine in spinal Anesthesia of opium-addicted patients. Methods: In a double-blind randomized clinical trial, 60 American...

متن کامل

Block-dependent sedation during epidural anaesthesia is associated with delayed brainstem conduction.

BACKGROUND Neuraxial anaesthesia produces a sedative and anaesthetic-sparing effect. Recent evidence suggests that spinal cord anaesthesia modifies reticulo-thalamo-cortical arousal by decreasing afferent sensory transmission. We hypothesized that epidural anaesthesia produces sensory deafferentation-dependent sedation that is associated with impairment of brainstem transmission. We used brains...

متن کامل

Changes in bispectral index values during lumbar arthrodesis.

EDITOR: Several authors have reported sudden increases of the bispectral index values during different procedures such as endoscopic shoulder surgery [1], deep hypothermic circulatory arrest [2] or after using an upper-body blanket for warming [3]. In addition, spurious bispectral index values can be observed when the electromyogram activity of the bispectral index monitor reaches a value of 50...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 106 2  شماره 

صفحات  -

تاریخ انتشار 2011