A linear sigmoid colon passage method by left twisting

نویسندگان

  • Satoshi Awazu
  • Risa Araki
  • Toshihiko Awazu
چکیده

2 Satoshi Awazu, Risa Araki, Toshihiko Awazu 3 4 Awazu Hospital, Nagasaki, Japan 5 6 Address correspondence to Satoshi Awazu, Awazu Hospital, Nagasaki 851-0251, Japan. Phone: 7 +81-95-826-9088. E-mail: [email protected]. 8 9 10 ABSTRACT 11 12 We previously reported that the sigmoid-descending colon junction becomes linear and 13 the colonoscope can be readily inserted into the descending colon in the left semiprone 14 position. In addition, we encountered a situation whereby the sigmoid colon becomes more 15 linear and the colonoscope can be more straightly inserted in the sigmoid colon when the 16 colonoscope is inserted with twisting to the left in the left semiprone position. Therefore, 17 our new insertion method was devised so that the colonoscope neutral position was rotated 18 45 degrees to the left compared to our conventional insertion method, and this method was 19 performed to determine whether the colonoscope looping rate in the sigmoid colon can be 20 reduced. The colonoscope looping rate in the sigmoid colon could be reduced by using our 21 new insertion method. These results suggest that safer colonoscope insertion is possible by 22 using our new insertion method compared with our conventional insertion method. 23 24 25 INTRODUCTION 26 27 Colonoscope looping in the sigmoid colon is considered to cause intestinal perforation 28 (Lüning et al., 2007; Magdeburg et al., 2008; Shah et al., 2000). 29 We previously reported that the sigmoid-descending colon junction becomes linear and 30 the colonoscope can be readily inserted into the descending colon in the left semiprone 31 position (Awazu, Araki & Awazu, 2012). Therefore, we considered that the sigmoid colon 32 also becomes linear and the colonoscope can be readily inserted in the sigmoid colon in the 33 left semiprone position. 34 In addition, we encountered a situation whereby the sigmoid colon becomes more linear 35 and the colonoscope can be more straightly inserted in the sigmoid colon when the 36 colonoscope is inserted with twisting to the left in the left semiprone position (Fig. 1). 37 Therefore, we considered that the colonoscope can be more readily inserted in the sigmoid 38 colon when the colonoscope is inserted with twisting to the left in the left semiprone 39 position. 40

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A linear sigmoid colon passage method in colonoscopy

2 Satoshi Awazu, Risa Araki, Toshihiko Awazu 3 4 Awazu Hospital, Nagasaki, Japan 5 6 Address correspondence to Satoshi Awazu, Awazu Hospital, Nagasaki 851-0251, Japan. Phone: 7 +81-95-826-9088. E-mail: [email protected]. 8 9 10 ABSTRACT 11 12 A previous study revealed loop formation of the colonoscope in the sigmoid colon in 13 79% of patients. Colonoscope looping in the sigmoid colon is ...

متن کامل

Ileosigmoid knot – A Surgeon’s Nightmare Keywords: Ileosigmoid knot, Gangrenous sigmoid colon and ileum, Hartmann’s procedure

Ileosigmoid knot, also known as compound volvulus, is an unusual and a rare cause of intestinal obstruction. We are reporting a case of ileosigmoid knot in a 30-year-old male, who presented with lower abdominal pain. On examination, there was tenderness in the suprapubic area and later, the patient developed features of peritonitis. Exploratory laparotomy revealed a large volume of haemorrhagic...

متن کامل

Volvulus of the Sigmoid Colon during Pregnancy: A Case Report

Colonic obstruction due to sigmoid colon volvulus during pregnancy is a rare but complication with significant maternal and fetal mortality. We describe a case of sigmoid volvulus in a patient with 33 weeks of gestation that developed complete necrosis of the left colon. Case. 27-year-old woman was admitted with 3 days of abdominal distention, vomit, and the stoppage of the passage of gases and...

متن کامل

Topological current algebras in two dimensions

Two-dimensional topological field theories possessing a non-abelian current symmetry are constructed. The topological conformal algebra of these models is analysed. It differs from the one obtained by twisting the N = 2 superconfor-mal models and contains generators of dimensions 1, 2 and 3 that close a linear algebra. Our construction can be carried out with one and two bosonic currents and th...

متن کامل

Recurrent Volvulus of the Sigmoid Colon Cured by Complete Sigmoidectomy

section was performed by myself and the volvulus again reduced. To prevent a recurrence of the twisting, the colon was stitched to the abdominal parieties. It was greatly liypertrophied and harboured a mass of constipated feces which probably caused the volvulus. The patient gave a history of long continued obstinate constipation. He returned again in the following March when I performed abdomi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013