The Advanced Camera for Surveys is equipped with three prisms in the Solar Blind (SBC) and High Resolution (HRC) Channels, which together cover the 1150 – 3500 Å range, albeit at highly non-uniform spectral resolution. We present new wavelengthand flux calibrations of the SBC (PR110L and PR130L) and HRC (PR200L) prisms, based on calibration observations obtained in Cycle 13. The calibration products are available to users via the ST-ECF/aXe web pages, and can be used directly with the aXe package. We discuss our calibration strategy and some caveats specific to slitless prism spectroscopy.

منابع مشابه

Slitless Spectroscopy with the Advanced Camera for Surveys

The Advanced Camera for Surveys (ACS) enables slitless, low-resolution spectroscopic imaging in its three channels. The most-used modes are grism imaging with the WFC and the HRC at a resolution of 40 and 24 Å/pixel, respectively. In the far-UV there are two prisms for the SBC and one prism for the HRC in the near-UV. An overview of the slitless spectroscopic modes of the ACS is presented toget...

متن کامل

Recent developments of the ACS spectral extraction software aXe

The software package aXe provides comprehensive spectral extraction facilities for all the slitless modes of the ACS, covering the Wide Field Channel (WFC) grism, the High Resolution Channel (HRC) grism and prism and the Solar Blind Channel (SBC) prisms. The latest developments to the package apply to all ACS slitless modes leading to improved spectral extraction. Many thousands of spectra may ...

متن کامل

Wavelength and Flux calibration of the ACS/HRC PR200L prism

Wavelengthand flux calibrations are presented for the ACS/HRC PR200L slitless spectroscopy mode. The calibrations were derived from Cycle 13 observations of a QSO at redshift z=0.836 and a planetary nebula in the LMC (for the wavelength calibration) and two white dwarf standards (for the flux calibration), and are made available to users as configuration files for the aXe software package. Both...

متن کامل

Wavelength and Flux calibration of the ACS/SBC PR110L and PR130L prisms

Wavelengthand flux calibrations are presented for the ACS/SBC PR110L and PR130L slitless spectroscopy modes. The calibrations were derived from Cycle 13 observations of two QSOs at redshift z=0.098 and z=0.168 (for the wavelength calibration) and two white dwarf standards (for the flux calibration), and are made available to users as configuration files for the aXe software package. Both the tr...

متن کامل

Updated Wavelength Calibration for the WFC/G800L grism

A revised wavelength calibration is presented for the G800L grism used with the ACS Wide Field Channel. Combining existing calibration data with new observations of the Wolf-Rayet star WR96, we achieve improved coverage of the WFC field-of-view. Deviations from the previously published wavelength calibration are less than 1 pixel (40 Å) for the +1st order over nearly the entire field. The new w...