Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness.

نویسندگان

  • Werner H Mörmann
  • Bogna Stawarczyk
  • Andreas Ender
  • Beatrice Sener
  • Thomas Attin
  • Albert Mehl
چکیده

OBJECTIVES This study determined the two-body wear and toothbrushing wear parameters, including gloss and roughness measurements and additionally Martens hardness, of nine aesthetic CAD/CAM materials, one direct resin-based nanocomposite plus that of human enamel as a control group. MATERIALS AND METHODS Two-body wear was investigated in a computer-controlled chewing simulator (1.2 million loadings, 49N at 1.7Hz; 3000 thermocycles 5/50°C). Each of the 11 groups consisted of 12 specimens and 12 enamel antagonists. Quantitative analysis of wear was carried out with a 3D-surface analyser. Gloss and roughness measurements were evaluated using a glossmeter and an inductive surface profilometer before and after abrasive toothbrushing of machine-polished specimens. Additionally Martens hardness was measured. Statistically significant differences were calculated with one-way ANOVA (analysis of variance). RESULTS Statistically significant differences were found for two-body wear, gloss, surface roughness and hardness. Zirconium dioxide ceramics showed no material wear and low wear of the enamel antagonist. Two-body wear of CAD/CAM-silicate and -lithium disilicate ceramics, -hybrid ceramics and -nanocomposite as well as direct nanocomposite did not differ significantly from that of human enamel. Temporary polymers showed significantly higher material wear than permanent materials. Abrasive toothbrushing significantly reduced gloss and increased roughness of all materials except zirconium dioxide ceramics. Gloss retention was highest with zirconium dioxide ceramics, silicate ceramics, hybrid ceramics and nanocomposites. Temporary polymers showed least gloss retention. Martens hardness differed significantly among ceramics, between ceramics and composites, and between resin composites and acrylic block materials as well. CONCLUSIONS All permanent aesthetic CAD/CAM block materials tested behave similarly or better with respect to two-body wear and toothbrushing wear than human enamel, which is not true for temporary polymer CAD/CAM block materials. Ceramics show the best gloss retention compared to hybrid ceramics, composites and acrylic polymers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of professional dental prophylaxis on the surface gloss and roughness of CAD/CAM restorative materials

BACKGROUND This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). MATERIAL AND METHODS Af...

متن کامل

Evaluation of hardness and wear resistance of interim restorative materials

BACKGROUND The interim restorative materials should have certain mechanical properties to withstand in oral cavity. The aim of this study was to evaluate the hardness and wear resistance of interim restorative materials. MATERIALS AND METHODS Fifteen identical rectangular shape specimens with dimensions of 2 mm × 10 mm × 30 mm were made from 7 interim materials (TempSpan, Protemp 3 Garant, Re...

متن کامل

Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists

OBJECTIVE Evaluation of wear behavior of computer-aided design/computer-aided manufacturing (CAD/CAM) crowns from various restorative materials and natural antagonists. METHOD Full CAD/CAM crowns fabricated with nanoceramic resin (Lava Ultimate (LU)), a glass ceramic in a resin interpenetrating matrix (Vita Enamic (VE)) and a lithium silicate reinforced ceramic enriched with zirconia (Vita Su...

متن کامل

Effect of Finishing /Polishing Techniques and Time on Surface Roughness of Silorane and Methacrylate Based Restorative Materials

Aim: The study evaluated the efficiency of various finishing and polishing systems and the effect of finishing and polishing time by using various procedures on surface roughness and hardness of silorane based (FiltekP90) and methacrylate based (Z100) restorative materials. Method: The surface roughness and surface hardness were measured using a profilometer and Vickers hardness tester respecti...

متن کامل

Esthetic Rehabilitation of Smile with Minimally Invasive Preparations and Thin Laminate Ceramic Veneers Using Chairside CAD/CAM System

Submit Manuscript | http://medcraveonline.com Teeth presenting diastema and misalignment are a common finding in the anterior maxillary dentition, and this fact can strongly affect the appearance of a smile, besides being displeasing for the patients.1 The current literature suggests several approaches for the correction of diastemas and misaligned teeth, such as orthodontic intervention, direc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the mechanical behavior of biomedical materials

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2013