Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.

نویسندگان

  • Jonathan T Bravman
  • Michal L Taylor
  • Todd Baldini
  • Armando F Vidal
چکیده

Higher rates of poor outcomes in displaced midshaft clavicle fractures treated nonoperatively have recently been reported. Along with expanding indications for operative fixation and increasing application of locked plate constructs, it is unknown whether complications related to bicortical penetration of the clavicle can be avoided using unicortical fixation. The purpose of this study is to compare the biomechanical properties of unicortical and bicortical fixation in precontoured vs manually contoured locking clavicle plates. Forty-eight Sawbone composite human clavicle specimens (item #3408; Pacific Research Laboratories, Vashon, Washington) with a midshaft clavicle osteotomy were reduced and plated in 8 specimens each using a bicortical and unicortical fixation for each of 3 locked plate constructs (3.5-mm LCP Reconstruction Plate; 3.5-mm LCP Superior Clavicle Plate; 3.5-mm LCP Superior Anterior Clavicle Plate; Synthes, Inc, West Chester, Pennsylvania). Specimens were tested for stiffness in axial torsion and cantilever bending and then loaded to failure in 3-point bending. Data were analyzed using 2-way analysis of variance and Tukey's test (P<.05). No significant differences were found between unicortical and bicortical fixation in failure load, cantilever bending, and cross body stiffness. Bicortical fixation was significantly stiffer than unicortical fixation in torsion only for the same plates. Significant differences also existed between plates in torsion. Unicortical locked plate fixation may be a reasonable option in the treatment of displaced midshaft clavicle fracture fixation to avoid complications associated with posteroinferior hardware penetration following clavicle fracture fixation based on the biomechanical performance of these constructs. However, it remains unclear whether these differences will be clinically significant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures.

PURPOSE The objective of this study was to assess the biomechanical properties of bicortical locking screws, unicortical locking screws, and unicortical far-cortex-abutting locking screw fixation in a cadaver model of comminuted midshaft clavicle fractures stabilized with a locking plate placed on the superior surface of the clavicle. METHODS Nine pairs of adult fresh-frozen cadaver clavicles...

متن کامل

A biomechanical study comparing plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to cyclic loading.

The use of bicortical screws to fix metacarpal fractures has been suggested to provide no added biomechanical advantage over unicortical screw fixation. However, this was only demonstrated in static loading regimes, which may not be representative of biological conditions. The present study was done to determine whether similar outcomes are obtained when cyclic loading is applied. Transverse mi...

متن کامل

Plate Versus Intramedullary Fixation Care of Displaced Midshaft Clavicular Fractures

In recent decades, there has been a growing trend to the operative treatment of displaced midshaft clavicular fractures. Open reduction and internal plate fixation, and intramedullary nailing fixation are 2 of the widely used techniques for operative treatment, but the optimal fixation method for these types of fractures remains a topic of debate. The objective of this study was to determine th...

متن کامل

The Comparison of Results of Treatment of Midshaft Clavicle Fracture between Operative Treatment with Plate and Non-Operative Treatment

Background:  Clavicle fractures are common and usually heal without complications. In this study, we evaluated the outcomes of non-operative versus operative management of displaced fractures.   Methods:  In a prospective clinical trial study, sixty-five patients with displaced clavicle mid-shaft fractures were nonrandomly divided in two treatment groups. The first group underwent non-operative...

متن کامل

Stability of Unicortical versus Bicortical Metacarpal Fracture Internal Fixation Trial (SUBMIT): study protocol for a randomized controlled trial

BACKGROUND Metacarpal fractures are common, accounting for 40 % of all hand injuries. The use of plates for the fixation of these fractures allows early aggressive hand therapy post-operatively, reducing post-operative stiffness. Traditionally, bicortical fixation is the standard practice, where both dorsal and palmar cortices of the metacarpal are drilled through, with screws engaging both cor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 38 5  شماره 

صفحات  -

تاریخ انتشار 2015