Computerised intrapartum diagnosis of fetal hypoxia based on fetal heart rate monitoring and fetal pulse oximetry utilising wavelet analysis and SOM neural networks
نویسندگان
چکیده
Objective: The development of an automated computerised system that will assist the early intrapartum diagnosis of fetal hypoxia. The proposed method is based on 1) a signal processing method named wavelet transform in order to estimate the power in different frequency ranges in various fetal states 2) the analysis of the continuous fetal pulse oximetry recordings (FSpO2) and 3) the utilisation of the Self-Organising Map (SOM) neural network in order to categorise different fetal heart rate (FHR) patterns. Methods. Data collection: Data were collected from 61 women during labor in the 2 University Clinic of Obstetrics & Gynaecology, "Aretaeion" Hospital, University of Athens. Fourteen cases, with pH < 7.2 were the risk group. The Cardiotocogram (CTG) and the FSpO2 have been recorded during labour, using the Corometrics series 120 cardiotocograph combined with fetal pulse oximeter. Wavelet based analysis: For each 10-minute period we applied wavelet multi-resolution analysis in order to address the problem of long-term non-stationary behaviour of the fetal heart rate tracings and to estimate the power in different frequency ranges. The estimated power corresponds to the variations of the FHR in a given frequency range. Statistical analysis of the FSpO2: For each 10-minute period we calculated the percentage of time in which the SpO2 was less than 30%. Classification: In order to categorize different 10-minute fetal heart rate patterns we used the SOM neural network with unsupervised training. Such network consists of two layers: an input layer and a two-dimensional output layer. The characteristic of this neural network is to learn to recognize groups of similar input vectors, in such a way that units near to each other in the output layer respond to similar input vectors. In this way, a mapping process takes place and input data vectors with similar features are mapped into the same area of the SOM. Results: For each 10-minute fetal heart rate pattern we estimated the power in the frequency ranges between 0.03 to 0.06 Hz and 0.06 to 0.09 Hz respectively and the percentage of time in which the SpO2 was less than 30%. These three parameters formed the input vectors of the SOM neural network. After training of the neural network and mapping, the two-dimensional output topology showed an area characterized by high power values and very low oxygen saturation. We have noticed that when one or two 10-minute period patterns were located in this area, the pH value was below 7.2 Conclusions: We believe that computerised analysis of the FHR monitoring and pulse oximetry based on the combination of wavelet analysis and neural networks is a very promising technique in objective intrapartum diagnosis of fetal hypoxia.
منابع مشابه
Classification of Fetal Heart Rate Tracings Based on Wavelet-transform & Self-organizing-map Neural Networks
The objective of the present study is the development of an automated computerized system that will assist the early diagnosis of fetal hypoxia. We demonstrate that it is possible to distinguish between healthy subjects and acidemic fetuses by way of wavelet transform analysis of the fetal heart rate recordings and fetal pulse oximetry (FSpO2). We focus on the values of the standard deviation o...
متن کاملIntrapartum fetal surveillance.
Intrapartum hypoxia was thought to contribute to the incidence of cerebral palsy, seizures and mental retardation. Electronic fetal monitoring was expected to prevent or reduce this incidence. Electronic fetal monitoring has a high false positive rate and fetal blood sampling, which is an invasive procedure, only allows an intermittent assessment. Efforts are being made to improve fetal heart r...
متن کاملRational approach to electronic fetal monitoring during labour in 'all' resource settings
Electronic fetal monitoring (EFM) involves the use of cardiotocograph (CTG) to asses fetal wellbeing during labour in order to detect intrapartum fetal hypoxia early so as to institute timely and appropriate action. Indeed, when CTG was introduced into obstetric practice in the 1960s, it was expected to prevent perinatal brain injury and reduce the incidence of short term (neonatal admissions, ...
متن کاملTrans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry.
Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to elect...
متن کاملFIGO consensus guidelines on intrapartum fetal monitoring: Adjunctive technologies.
Cardiotocography (CTG) has a high sensitivity but only a limited specificity in predicting fetal hypoxia/acidosis [1]. In other words, a normal CTG is reassuring regarding the state of fetal oxygenation as hypoxia/acidosis is generally restricted to cases with suspicious or pathological patterns (see the definitions given in the CTG chapter [1]). However, a large number of fetuses with the latt...
متن کامل