Homogeneous, micelle quenching fluoroimmunoassay for detecting amphetamines in urine.

نویسندگان

  • C J Halfman
  • D W Jay
چکیده

We developed a homogeneous fluoroimmunoassay for detecting amphetamines in urine. Only fluorescence intensity need be measured because the emission of non-protein-bound fluorescein-labeled amphetamine is preferentially quenched by detergent micelles. In a previous reported prototype assay system for measuring gentamicin in serum we used fluorescein and dodecyl sulfate (Anal Chem 1985; 57:1928-30). We have found that favorable hydrophobic and (or) ionic character of the analyte and unfavorable polar and (or) ionic character of the fluor are important determinants of the desired interactions. An anionic detergent and fluorescein, therefore, should be appropriate for apolar of cationic analytes, such as gentamicin and amphetamines. A greater [H+] at the anionic micelle surface is important for quenching emission from the fluor moiety. Millimolar concentrations of dodecyl sulfate rapidly denature immunoglobulin unless hapten is bound with sufficiently high affinity. Affinity was sufficiently high for the antibody used in the prototype gentamicin assay but not for the amphetamine antibody. Thus for the amphetamine assay, we used a non-denaturing detergent, dodecyl(oxyethylene)12 sulfate. The assay requires 30 microL of specimen in 2 mL of total assay volume. Amphetamine(d-,dl-, and meth-), at a concentration of 1 mg per liter of urine, is readily detected.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distance-independent quenching of quantum dots by nanoscale-graphene in self-assembled sandwich immunoassay.

A promising one-step homogeneous fluoroimmunoassay based on nanoscale-graphene sheets as powerful fluorescence acceptors and CdTe quantum dots as vigorous donors was designed to detect trace biomarker protein with distance-independent quenching efficiency, which significantly broke the distance limit (100 Å) in traditional fluorescent biosensors.

متن کامل

Homogeneous time-resolved fluoroimmunoassay of thyroxin in serum.

We describe a rapid, simple nonseparation fluoroimmunoassay for determination of thyroxin in serum. The assay is based on the labeling of thyroxin directly with a fluorescent europium chelate, the fluorescence of which is quenched on binding to an antithyroxin antibody. With the assay buffer we used, maximum quenching is 90%. The rapid achievement of equilibrium in the assay solution, regardles...

متن کامل

In Vitro Cytotoxic Activity and Binding Properties of Curcumin in the Presence of β-Casein Micelle Nanoparticles

Curcumin (CUR) is the active curcuminoid with many physiological, biochemical, and pharmacological properties. Solubility and stability of CUR is the limiting factors for realizing its therapeutic potential. Bovine β-casein is an abundant milk protein that is highly amphiphilic and self-assembles into stable micellar nanoparticles in aqueous solution. β-Casein nanoparticle can solubilize CUR mo...

متن کامل

Routine analysis of amphetamine class drugs as their naphthaquinone derivatives in human urine by high-performance liquid chromatography.

We describe a simple HPLC method which is suitable for the routine confirmation of immunoassay positive amphetamine urine samples. The precolumn derivisation method employing sodium naphthaquinone-4-sulphonate was found to have adequate sensitivity, selectivity and precision for the measurement of amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetam...

متن کامل

Measurement of estrone-3-glucuronide in urine by rapid, homogeneous time-resolved fluoroimmunoassay.

We describe a liquid-phase nonseparation time-resolved fluorescence immunoassay for measuring estrone-3-glucuronide in undiluted urine. The sensitivity, specificity, and accuracy are similar to those for a conventional separation fluoroimmunoassay or radioimmunoassay, but the speed, convenience, precision, reliability, and clinical utility of the new method are more advantageous. The labeled an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 9  شماره 

صفحات  -

تاریخ انتشار 1986