Evaluation of the Image Quality Index in mosaics
نویسندگان
چکیده
The focus of this study is the evaluation of the Image Quality Index (IQI) in mosaics generated from aerial images collected by a Remotely Piloted Aircraft (RPA). The software packages used to generate the mosaics were PhotoModeler, PhotoScan and Pix4Dmapper. The mosaic generated by the software PhotoScan was superior to the others visually, but inferior to the software PhotoModeler in relation to the average of the quality indexes calculated. The average values of the IQIs obtained for the mosaics generated by the software packages PhotoModeler, PhotoScan and Pix4Dmapper were 0.98118, 0.94814 and 0.93256, respectively. An analysis of variance was performed but did not present a significant difference.
منابع مشابه
Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose
Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...
متن کاملA Novel Image Structural Similarity Index Considering Image Content Detectability Using Maximally Stable Extremal Region Descriptor
The image content detectability and image structure preservation are closely related concepts with undeniable role in image quality assessment. However, the most attention of image quality studies has been paid to image structure evaluation, few of them focused on image content detectability. Examining the image structure was firstly introduced and assessed in Structural SIMilarity (SSIM) measu...
متن کاملQualitative evaluation of filter function in brain SPECT [Persian]
Introduction: Filtering can greatly affect the quality of clinical images. Determining the best filter and the proper degree of smoothing can help to ensure the most accurate diagnosis. Methods: Forty five patient’s data aquired during brain phantom SPECT studies were reconstructed using filtered back-projection technique. The ramp, Shepp-Logan, Cosine, Hamming, Hanning, Butterworth, Metz...
متن کاملA New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT
ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance. In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کامل