Reliability of the nitrogen washin-washout technique to assess end-expiratory lung volume at variable PEEP and tidal volumes

نویسندگان

  • Jean-Christophe Richard
  • Céline Pouzot
  • Alfredo Morales Pinzón
  • Juan Sebastian Torres González
  • Maciej Orkisz
  • Bruno Neyran
  • Marcela Hernández Hoyos
  • Franck Lavenne
  • Claude Guerin
چکیده

BACKGROUND End-expiratory lung volume measurement by the nitrogen washin-washout technique (EELVWI-WO) may help titrating positive end-expiratory pressure (PEEP) during acute respiratory distress syndrome (ARDS). Validation of this technique has been previously performed using computed tomography (EELVCT), but at mild PEEP levels, and relatively low fraction of inspired oxygen (FiO2), which may have insufficiently challenged the validity of this technique. The aims of this study were (1) to evaluate the reliability of EELVWI-WO measurements at different PEEP and V T during experimental ARDS and (2) to evaluate trending ability of EELVWI-WO to detect EELV changes over time. METHODS ARDS was induced in 14 piglets by saline lavage. Optimal PEEP was selected during a decremental PEEP trial, based on best compliance, best EELVWI-WO, or a PEEP-FiO2 table. Eight V T (4 to 20 mL · kg(-1)) were finally applied at optimal PEEP. EELVWI-WO and EELVCT were determined after ARDS onset, at variable PEEP and V T. RESULTS EELVWI-WO underestimated EELVCT with a non-constant linear bias, as it decreased with increasing EELV. Limits of agreement for bias were ±398 mL. Bias between methods was greater at high PEEP, and further increased when high PEEP was combined with low V T. Concordance rate of EELV changes between consecutive measurements was fair (79%). Diagnostic accuracy was good for detection of absolute EELV changes above 200 mL (AUC = 0.79). CONCLUSIONS The reliability of the WI-WO technique is critically dependent on ventilatory settings, but sufficient to accurately detect EELV change greater than 200 mL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and precision of end-expiratory lung-volume measurements by automated nitrogen washout/washin technique in patients with acute respiratory distress syndrome

INTRODUCTION End-expiratory lung volume (EELV) is decreased in acute respiratory distress syndrome (ARDS), and bedside EELV measurement may help to set positive end-expiratory pressure (PEEP). Nitrogen washout/washin for EELV measurement is available at the bedside, but assessments of accuracy and precision in real-life conditions are scant. Our purpose was to (a) assess EELV measurement precis...

متن کامل

Nitrogen washout/washin, helium dilution, and computed tomography in the assessment of end-expiratory lung volume

INTRODUCTION End expiratory lung volume (EELV) measurement in the clinical setting is routinely performed using the helium dilution technique. A ventilator that implements a simplified version of the nitrogen washout/washin technique is now available. We compared the EELV measured by spiral computed tomography (CT) taken as gold standard with the lung volume measured with the modified nitrogen ...

متن کامل

Correction: Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume

Comparison of end expiratory lung volume (EELV) measured by the helium dilution technique and the nitrogen washout/ washin method. (a) The EELV measured by the helium dilution as a function of the EELV measured by nitrogen washout/washin method (EELV helium dilution = -111.85 + 0.89 × EELV GE, r2 = 0.82, p < 0.00001). (b) The BlandAltman plot of the EELV measured with the nitrogen washout/washi...

متن کامل

Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume

Introduction End expiratory lung volume (EELV) measurement in the clinical setting is routinely performed using the helium dilution technique. A ventilator that implements a simplified version of the nitrogen washout/washin technique is now available. We compared the EELV measured by spiral computed tomography (CT) taken as gold standard with the lung volume measured with the modified nitrogen ...

متن کامل

Lung volumes and lung volume recruitment in ARDS: a comparison between supine and prone position

BACKGROUND The use of positive end-expiratory pressure (PEEP) and prone position (PP) is common in the management of severe acute respiratory distress syndrome patients (ARDS). We conducted this study to analyze the variation in lung volumes and PEEP-induced lung volume recruitment with the change from supine position (SP) to PP in ARDS patients. METHODS The investigation was conducted in a m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014