Lessons learnt from early failure of a patient trial with a polymer-on-polymer resurfacing hip arthroplasty

نویسندگان

  • Job L C Van Susante
  • Nico Verdonschot
  • L Paul A Bom
  • Pawel Tomaszewski
  • Pat Campbell
  • Edward Ebramzadeh
  • B Wim Schreurs
چکیده

Background and purpose - Hip resurfacing (HR) is a treatment option promoted for hip arthritis in young and active patients. However, adverse reactions to metal are a concern and the search for non-metallic bearing options proceeds. We present the first clinical study performed in patients using a newly developed hydrophilic polymer-on-polymer hip resurfacing device. Patients and methods - After performing extensive hip simulator tests, biocompatibility testing and animal tests (ISO 14242-1,3; 10993-3,4,5,10,11), approval was obtained from the IRB committee to enroll 15 patients in the first clinical study in humans using this experimental polymer-on-polymer hip resurfacing device. All surgeries were done by 2 experienced hip resurfacing surgeons. Clinical scores and standard radiographs as well as routine MRIs were obtained at regular intervals. Results - The surgical technique proved feasible with successful implantation of the new device using PMMA cement fixation on both sides without complications. Postoperative imaging revealed a well-positioned and well-fixed polymer resurfacing hip arthroplasty in all 4 initial cases. All 4 patients were free of pain and had good function for the first 2 months. However, in all 4 cases early cup loosening occurred between 8 and 11 weeks after surgery, necessitating immediate closure of the study. All 4 patients had a reoperation and were revised to a conventional THA. Retrieval analyses confirmed early cup loosening at the implant-cement interface in all 4 cases. The femoral components remained well attached to the cement. The periprosthetic tissues showed only small amounts of polymeric wear debris and there was only a very mild inflammatory reaction to this. Interpretation - Early cup loosening mandated a premature arrest of this study. After additional laboratory testing this failure mode was found to be the result of a small, yet measurable contraction in the cup size after exposing these implants to biological fluid divalent ion fluctuations in vivo. Currently used preclinical tests had failed to detect this failure mechanism. Modification of the polymer is essential to overcome these problems and before the potential of a polymer-on-polymer resurfacing arthroplasty may be further evaluated in patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-effectiveness of total hip arthroplasty versus resurfacing arthroplasty: economic evaluation alongside a clinical trial

OBJECTIVE To report on the relative cost-effectiveness of total hip arthroplasty and resurfacing arthroplasty (replacement of articular surface of femoral head only) in patients with severe arthritis suitable for hip joint resurfacing arthroplasty. DESIGN Cost-effectiveness analysis on an intention-to-treat basis of a single-centre, single-blind randomised controlled trial of 126 adult patien...

متن کامل

A randomised controlled trial of total hip arthroplasty versus resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint

BACKGROUND Hip replacement (arthroplasty) surgery is a highly successful treatment for patients with severe symptomatic arthritis of the hip joint. For older patients, several designs of Total Hip Arthroplasty have shown excellent results in terms of both function and value for money. However, in younger more active patients, there is approximately a 50% failure rate at 25 years for traditional...

متن کامل

Hip resurfacing arthroplasty.

Hip resurfacing arthroplasty is a type of hip replacement that involves capping the femoral head and preserving bone of the proximal femur. Metal-on-metal surface replacements have been manufactured since the early 1990s. Recent studies indicate excellent clinical results with low failure rates at 1- to 5-year follow-up. Although these early results are encouraging, resurfacing devices must be ...

متن کامل

Risk factor analysis for early femoral failure in metal-on-metal hip resurfacing arthroplasty: the effect of bone density and body mass index

BACKGROUND The importance of appropriately selecting patients based on factors such as bone mineral density, body mass index, age, gender, and femoral component size has been demonstrated in many studies as an aid in decreasing the rate of revisions and improving the outcomes for patients after hip resurfacing arthroplasty (HRA); however, there are few published studies quantitatively specifyin...

متن کامل

Sex differences in the morphological failure patterns following hip resurfacing arthroplasty

BACKGROUND Metal-on-metal hybrid hip resurfacing arthroplasty (with a cementless acetabular component and a cemented femoral component) is offered as an alternative to traditional total hip arthroplasty for the young and active adult with advanced osteoarthritis. Although it has been suggested that women are less appropriate candidates for metal-on-metal arthroplasty, the mechanisms of prosthes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 89  شماره 

صفحات  -

تاریخ انتشار 2018