چکیده

We studied the analytical and clinical performance of six methods for creatine kinase (EC 2.7.3.2) isoenzyme MB (CK-MB): three immunoassays (Behring, Hybritech, and International Immunoassay Labs); one immunoinhibition assay (Roche); one immunoinhibition/column method (Du Pont); and one electrophoretic method (Beckman). Between-day precision for all kits was poor at the upper reference limit. All methods gave results linearly related to CK-MB concentration and all were free from CK-MM, CK-BB, and adenylate kinase interference. Only the Du Pont method was adversely affected by atypical isoenzymes. For diagnosis of acute myocardial infarction in a coronary care population (n = 40; prevalence = 45%), all methods were approximately 95% efficient, when appropriate reference criteria were used. Some manufacturers fail to provide data for an appropriate (acutely ill, non-infarct) reference population; decreased diagnostic specificity may result from use of reference ranges based on results for healthy subjects. Expression of CK-MB as a percent of total CK degrades efficiency unless total CK is markedly increased.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of the Inhibition of Mitochondrial Creatine Kinase Activity on the Clinical Diagnosis of Suspected Acute Myocardial Infarction

Background: Creatine kinase isoenzyme MB (CK-MB) activity using the immunoinhibition method has been measured in clinical laboratories. However, the presence of mitochondrial CK (MtCK) abnormally increases CK-MB activity when measured using the conventional method, which can lead to misdiagnosis of acute myocardial infarction (AMI). A new CK-MB activity assay kit that can inhibit MtCK activity ...

متن کامل

Analytical evaluation of methods for serum creatine kinase-MB. Electrophoresis, immunoinhibition and solid phase separation.

The purpose of this study was to evaluate immunoassay methods for the measurement of serum cardiac creatine kinase isoenzyme (CK-MB) with respect to sensitivity and specificity. The CK-MB electrophoretic assay (Helena Laboratories) was used as the reference. Two principles of immunoassay were included in the evaluation,--immunoinhibition and solid phase separation. The direct immunoinhibition t...

متن کامل

Results of a nationwide survey of analyses for creatine kinase and creatine kinase isoenzymes.

More than 300 laboratories participated in an interlaboratory survey of creatine kinase (CK, EC 2.7.3.2) determinations in which they analyzed seven lyophilized samples for total CK and CK isoenzymes and furnished information about their methodology. The samples were not necessarily intended to mimic typical patients' specimens but rather to determine the analytical ability of the laboratories ...

متن کامل

Clinical and analytical evaluation of two immunoassays for direct measurement of creatine kinase MB with monoclonal anti-CK-MB antibodies.

We examined the clinical and analytical performance of two immunoassays (Becton Dickinson CK-MB; Ciba-Corning Magic Lite CK-MB) in which monoclonal anti-CK-MB antibodies are used for directly measuring creatine kinase (EC 2.7.3.2) isoenzyme MB (CK-MB) in serum, and also one electrophoretic method (Ciba-Corning). Within- and between-assay precision for both immunoassays was good at the upper ref...

متن کامل

Proficiency testing for creatine kinase isoenzyme CK-2 (CK-MB) in Ontario.

Three surveys of the measurement and interpretation of creatine kinase (CK; EC 2.7.3.2) isoenzyme 2 (CK-MB) were conducted in Ontario, Canada, in 1989. Of the clinical laboratories participating, 66% used immunological methods and 24% used electrophoretic methods. Although reference ranges and interpretative routines varied widely, 95% of the laboratories reported correct interpretations for 10...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 1 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1986