Eversion strength analysis of uninjured and functionally unstable ankles.

نویسندگان

  • T W Kaminski
  • D H Perrin
  • B M Gansneder
چکیده

OBJECTIVE Functional ankle instability (FAI) afflicts many athletes. Several causes of FAI have been implicated, including peroneal muscle weakness. Traditional musculoskeletal rehabilitation programs have focused on concentric muscle strength. The purpose of our study was to compare concentric and eccentric isokinetic and isometric eversion ankle strength measurements between subjects identified as having unilateral FAI and subjects having no history of inversion ankle sprain. DESIGN AND SETTING Employing a matched-pairs technique, subjects with no history of ankle injury were compared with subjects with unilateral FAI using isokinetic and isometric measures of eversion ankle strength. Strength testing was performed in a sports medicine clinic setting. SUBJECTS Forty-two subjects volunteered for this study: 21 subjects suffered from unilateral FAI (age = 19.3 +/- 1.1 years, wt = 84.0 +/- 9.5 kg, ht = 181.5 +/- 9.2 cm), while 21 subjects served as matched-paired controls (age = 19.5 +/- 1.2 years, wt = 82.5 +/- 10.9 kg, ht = 179.5 +/- 7.9 cm). MEASUREMENTS Ankle eversion concentric and eccentric strength (peak torque) was assessed at 0 degrees /s, 30 degrees /s, 60 degrees /s, 90 degrees /s, 120 degrees /s, 150 degrees /s, and 180 degrees /s using an isokinetic dynamometer. RESULTS We found no significant differences in concentric, eccentric, or isometric eversion ankle strength between the 2 groups of subjects. CONCLUSIONS The exact cause of FAI remains elusive. Based on our results, those who suffer from unilateral FAI do not appear to have eversion strength deficits. Unless clear evidence of weakness exists, clinicians may find that eversion strength training exercises are unnecessary. Future research should examine other causes of FAI, including reciprocal muscle group strength ratios and proprioception deficits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ankle musculature latency measurement to varing angles of sudden external oblique perturbation in normal functionally unstable ankles

 Abstract Background: Several studies have examined the reflex response of ankle musculature to sudden inversion in noninjured and injured subjects. To date, there have been no studies to determine the effect of versatile degrees & conditions of perturbation on the ankle musculature latency. The purpose of this study was to measure and determine whether there was a difference in ankle musculatu...

متن کامل

Eccentric plantar-flexor torque deficits in participants with functional ankle instability.

CONTEXT Inversion ankle sprains can lead to a chronic condition called functional ankle instability (FAI). Limited research has been reported regarding isokinetic measures for the plantar flexors and dorsiflexors of the ankle. OBJECTIVE To examine the isokinetic eccentric torque measures of the ankle musculature in participants with stable ankles and participants with functionally unstable an...

متن کامل

Eccentric/concentric ratios at selected velocities for the invertor and evertor muscles of the chronically unstable ankle.

OBJECTIVE The use of muscle balancing by the clinician to determine return to activity or discharge of a patient is not a well understood measure. Because of the lack of information on the poorly understood concept of eccentric/concentric (E/C) ratios at the ankle, the purpose was to determine the E/C ratios for the invertor and evertor muscles at various velocities in healthy and chronically u...

متن کامل

Peak and end range eccentric evertor/concentric invertor muscle strength ratios in chronically unstable ankles: comparison with healthy individuals.

The aim of this study was to evaluate the alterations in eccentric evertor/concentric invertor strength ratio and their importance in the chronically unstable ankle. Eight patients with chronic ankle instability (CAI) and nine healthy individuals participated in this study. Isokinetic concentric and eccentric invertor and evertor muscle strength measurement was carried out at an angular velocit...

متن کامل

Arthrometric measurement of ankle-complex motion: normative values.

CONTEXT Valid and reliable measurements of ankle-complex motion have been reported using the Hollis Ankle Arthrometer. No published normative data of ankle-complex motion obtained from ankle arthrometry are available for use as a reference for clinical decision making. OBJECTIVE To describe the distribution variables of ankle-complex motion in uninjured ankles and to establish normative refer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of athletic training

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 1999