Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study
نویسندگان
چکیده
PURPOSE To evaluate a digital high-speed camera combined with digital morphometry software for dynamic measurements of phakic intraocular lens movements to observe kinetic influences, particularly in fast direction changes and at lateral end points. MATERIALS AND METHODS A high-speed camera taking 300 frames per second observed movements of eight iris-claw intraocular lenses and two angle-supported intraocular lenses. Standardized saccades were performed by the patients to trigger mass inertia with lens position changes. Freeze images with maximum deviation were used for digital software-based morphometry analysis with ImageJ. RESULTS Two eyes from each of five patients (median age 32 years, range 28-45 years) without findings other than refractive errors were included. The high-speed images showed sufficient usability for further morphometric processing. In the primary eye position, the median decentrations downward and in a lateral direction were -0.32 mm (range -0.69 to 0.024) and 0.175 mm (range -0.37 to 0.45), respectively. Despite the small sample size of asymptomatic patients, we found a considerable amount of lens dislocation. The median distance amplitude during eye movements was 0.158 mm (range 0.02-0.84). There was a slight positive correlation (r=0.39, P<0.001) between the grade of deviation in the primary position and the distance increase triggered by movements. CONCLUSION With the use of a slit lamp-mounted high-speed camera system and morphometry software, observation and objective measurements of iris-claw intraocular lenses and angle-supported intraocular lenses movements seem to be possible. Slight decentration in the primary position might be an indicator of increased lens mobility during kinetic stress during eye movements. Long-term assessment by high-speed analysis with higher case numbers has to clarify the relationship between progressing motility and endothelial cell damage.
منابع مشابه
Implantation of an implantable collamer lens and iris cerclage for the treatment of Urrets-Zavalia syndrome
A 27-year-old woman with bilateral high myopia had anterior chamber iris-claw phakic intraocular lens implantation in her left eye under local anesthesia and with no intraoperative complications. The preoperative slit-lamp examination was normal, and she had no relevant past medical history. On the second postoperative day, patient developed fixed, dilated mydriasis, and one month later, an IOL...
متن کاملArtiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus
CASE A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. METHODS Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantatio...
متن کاملAutomated, computerized, feature-based phenotype analysis of slit lamp images of the mouse lens.
Longitudinal studies of a variety of transgenic mouse models for lens development can create substantial challenges in database management and analysis. We report a novel, automated, feature-based informatics approach to screening lens phenotypes in a large database of slit lamp images. Digital slit lamp images of normal and abnormal lenses in eyes of wild type (wt), SC1 null and SPARC null tra...
متن کاملMeasurement of corneal thickness by videopachymetry: preliminary results.
Corneal thickness measurements find applications in areas such as diagnosis and management of corneal disorders and corneal surgery. We present a technique for the measurement of corneal thickness using a CCD camera mounted on a slit-lamp biomicroscope and common image processing software. Thickness measurements were performed on three RGP contact lenses of known thickness with an average error...
متن کاملVideo indirect ophthalmoscopy using a hand-held video camera
Fundus photography in adults and cooperative children is possible with a fundus camera or by using a slit lamp-mounted digital camera. Retcam TM or a video indirect ophthalmoscope is necessary for fundus imaging in infants and young children under anesthesia. Herein, a technique of converting and using a digital video camera into a video indirect ophthalmoscope for fundus imaging is described. ...
متن کامل