Eyes with Large Disc Cupping and Normal Intraocular Pressure: Using Optical Coherence Tomography to Discriminate Those With and Without Glaucoma

نویسندگان

  • Tiago S. Prata
  • Syril Dorairaj
  • Luisa Trancoso
  • Fabio N. Kanadani
  • Luis G. Biteli
  • Rafael Furlanetto
  • Flavio S. Lopes
  • Mauro T. Leite
چکیده

We evaluated the ability of spectral-domain optic coherence tomography (SD-OCT) to differentiate large physiological optic disc cupping (LPC) from glaucomatous cupping in eyes with intraocular pressure (IOP) within the normal range. We prospectively enrolled patients with glaucoma or presumed LPC. Participants had optic discs with confirmed or suspected glaucomatous damage (defined as a vertical cup-to-disc ratio≥0.6), and all eyes had known untreated IOP<21 mmHg. For glaucomatous eyes, a reproducible glaucomatous visual field (VF) defect was required. LPC eyes required normal VF and no evidence of progressive glaucomatous neuropathy (follow-up≥30 months). Peripapillary retinal nerve fiber layer (pRNFL) and macular ganglion cell complex (GCC) thicknesses were obtained using SD-OCT. For all studied parameters of pRNFL and GCC thicknesses, eyes with glaucoma (n=36) had significantly thinner values compared to eyes with LPC (n=71; P<0.05 for all comparisons). In addition, pRNFL parameters had sensitivity of 66.7% and specificity of 83.1%, and GCC parameters had sensitivity of 61.2% and specificity of 81.7%. The combination of the two analyses increased the sensitivity to 80.6%. In conclusion, while evaluating patients with large optic disc cupping and IOP in the statistically normal range, SD-OCT had only limited diagnostic ability to differentiate those with and without glaucoma. Although the diagnostic ability of the pRNFL and the GCC scans were similar, these parameters yielded an increase in sensitivity when combined, suggesting that both parameters could be considered simultaneously in these cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Central corneal thickness and intraocular pressure relationship in eyes with and without previous lasik - Comparison of Goldmann applanation tonometer with pneumatonometer.

PURPOSE To investigate central corneal thickness (CCT) and intraocular pressure (IOP) relationship in eyes with and without previous corneal laser refractive surgery and to compare the estimates of two different tonometersGoldmann applanation and pneumatonometer. METHODS The study population included 234 glaucoma suspects who were referred to the glaucoma clinic with cup/disc ratios greater t...

متن کامل

گزارش یک مورد کاهش بینایی شدید یکطرفه و کاپینگ دو طرفه عصب اپتیک ثانویه به تومورمتاستاتیک مغز

Purpose: To report a case of unilateral severe visual loss and bilateral optic disc cupping secondary to brain metastasis of bronchogenic carcinoma Patient and findings: A 48 year-old woman presented with severe visual loss of left eye without redness or pain or any systemic findings .Clinical findings included decreased visual acuity of left eye to 4 m CF and (+3) positive Marcus-Gunn refle...

متن کامل

Peripapillary Intrachoroidal Cavitation and Optic Pit in a Case of High Myopia and Glaucoma

Purpose: To report a case of peripapillary intrachoroidal cavitation (choroidal schisis) and optic pit in a case of high myopia and open-angle glaucoma. Case report: A 30-year-old high myopic man was referred to our clinic for presumed peripapillary choroidal tumors. In funduscopy, there were two yellow-orange and slightly elevated peripapillary lesions in both eyes with indistinct margins. A s...

متن کامل

Lamina Cribrosa Defects and Optic Disc Morphology in Primary Open Angle Glaucoma with High Myopia

PURPOSE To investigate whether lamina cribrosa (LC) defects are associated with optic disc morphology in primary open angle glaucoma (POAG) eyes with high myopia. METHODS A total of 129 POAG patients and 55 age-matched control subjects with high myopia were evaluated. Three-dimensional scan images obtained by swept source optical coherence tomography were used to detect LC defects. Radial B-s...

متن کامل

Clinical Factors Associated with Lamina Cribrosa Thickness in Patients with Glaucoma, as Measured with Swept Source Optical Coherence Tomography

PURPOSE To investigate the influence of various risk factors on thinning of the lamina cribrosa (LC), as measured with swept-source optical coherence tomography (SS-OCT; Topcon). METHODS This retrospective study comprised 150 eyes of 150 patients: 22 normal subjects, 28 preperimetric glaucoma (PPG) patients, and 100 open-angle glaucoma patients. Average LC thickness was determined in a 3 x 3 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014