Ultrasound produced by a conventional therapeutic ultrasound unit accelerates fracture repair.

نویسندگان

  • Stuart J Warden
  • Robyn K Fuchs
  • Chris K Kessler
  • Keith G Avin
  • Ryan E Cardinal
  • Rena L Stewart
چکیده

BACKGROUND AND PURPOSE A recent novel application of ultrasound therapy is the treatment of bone fractures. The aim of this study was to investigate the effect on fracture repair of ultrasound produced by a conventional therapeutic ultrasound unit as used by physical therapists. SUBJECTS AND METHODS Bilateral midshaft femur fractures were created in 30 adult male Long-Evans rats. Ultrasound therapy was commenced on the first day after fracture and introduced 5 days a week for 20 minutes a day. Each animal was treated unilaterally with active ultrasound and contralaterally with inactive ultrasound. Active ultrasound involved a 2-millisecond burst of 1.0-MHz sine waves repeating at 100 Hz. The spatially averaged, temporally averaged intensity was set at 0.1 W/cm2. Animals were killed at 25 and 40 days after fracture induction, and the fractures were assessed for bone mass and strength. RESULTS There were no differences between fractures treated with active ultrasound and fractures treated with inactive ultrasound at 25 days. However, at 40 days, active ultrasound-treated fractures had 16.9% greater bone mineral content at the fracture site than inactive ultrasound-treated fractures. This change resulted in a 25.8% increase in bone size, as opposed to an increase in bone density, and contributed to active ultrasound-treated fractures having 81.3% greater mechanical strength than inactive ultrasound-treated fractures. DISCUSSION AND CONCLUSION These data indicate that ultrasound produced by a conventional therapeutic ultrasound unit as traditionally used by physical therapists may be used to facilitate fracture repair. However, careful interpretation of this controlled laboratory study is warranted until its findings are confirmed by clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR

We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...

متن کامل

بررسی اثر امواج اولتراسوند منقطع با فرکانس پایین بر تشکیل کال استخوانی تیبیا در خرگوش( ارزیابی رادیولوژیک و بیومکانیک)

Background and Objective: Application of low intensity ultrasound has been used for treatment of many diseases in medicine and has suggested for accelerating wound healing process, modifying scar tissue and relief of pain. The aim of this study was radiological and biomechanical evaluation of low-intensity pulsed ultrasound on callus formation of tibia in rabbit. Materials and Methods: In this...

متن کامل

Low-intensity pulsed ultrasound for bone healing: an overview.

Low-intensity ultrasound is a biophysical form of intervention in the fracture-repair process, which through several mechanisms accelerates healing of fresh fractures and enhances callus formation in delayed unions and nonunions. The goal of this review is to present the current knowledge obtained from basic science and animal studies, as well as existing evidence from clinical trials and case ...

متن کامل

Acceleration of Osseous Fracture Repair by Pulsed Low-intensity Ultrasound Therapy: a Preliminary Study

Low-intensity pulsed ultrasound in the range used in diagnostic applications, has been shown in many clinical studies to be an effective means to accelerate fracture repair. This paper presents the results obtained in a study effected in the hospital “Comandante Manuel Fajardo” in Havana, Cuba, between April 1999 and February 2000 with the use of this technique. A total of twelve ununited fract...

متن کامل

The effect of low-intensity therapeutic ultrasound in induced fracture of rat tibiae

OBJECTIVE To analyze the possible effects of low-intensity ultrasound on induced tibia fracture of rats in a dose commonly used in physical therapy treatments. METHODS Twenty male Wistar rats were divided into two groups with 10 animals each. In the ultrasound group (USG), the animals were submitted to bone fracture and treatment with therapeutic ultrasound (TUS). Ultrasonic parameters are: f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical therapy

دوره 86 8  شماره 

صفحات  -

تاریخ انتشار 2006