In vivo measurement of human wrist extensor muscle sarcomere length changes.
نویسندگان
چکیده
1. Human extensor carpi radialis brevis (ECRB) sarcomere length was measured intraoperatively in five subjects using laser diffraction. 2. In a separate cadaveric study, ECRB tendons were loaded to the muscle's predicted maximum tetanic tension, and tendon strain was measured to estimate active sarcomere shortening at the expense of tendon lengthening. 3. As the wrist joint was passively flexed from full extension to full flexion, ECRB sarcomere length increased from 2.6 to 3.4 microns at a rate of 7.6 nm/deg joint angle rotation. Correcting for tendon elongation during muscle activation yielded an active sarcomere length range of 2.44 to 3.33 microns. Maximal predicted sarcomere shortening accompanying muscle activation was dependent on initial sarcomere length and was always < 0.15 microns, suggesting a minimal effect of tendon compliance. 4. Thin filament lengths measured from electron micrographs of muscle biopsies obtained from the same region of the ECRB muscles were 1.30 +/- .027 (SE) microns whereas thick filaments were 1.66 +/- .027 microns long, suggesting an optimal sarcomere length of 2.80 microns and a maximum sarcomere length for active force generation of 4.26 microns. 5. These experiments demonstrate that human skeletal muscles can function on the descending limb of their sarcomere length-tension relationship under physiological conditions. Thus, muscle force changes during joint rotation are an important component of the motor control system.
منابع مشابه
Musculoskeletal balance of the human wrist elucidated using intraoperative laser diffraction.
This review describes a series of experiments in which sarcomere length was measured in human wrist muscles to understand their design. Sarcomere length measurements were combined with studies on cadaveric extremities to generate biomechanical models of human wrist function and to provide insights into the mechanism by which wrist strength balance is achieved. Intraoperative measurements of the...
متن کاملIntraoperative sarcomere length measurements reveal differential design of human wrist extensor muscles.
The design of the wrist extensor muscles was studied using a combination of intraoperative laser diffraction and biomechanical modelling of data obtained from human patients and previously published data. Intraoperatively, the change in sarcomere length per degree joint angle rotation (i.e. dSL/d omega) was measured as the wrist was moved from neutral to full flexion in both the extensor carpi ...
متن کاملSarcomere length varies with wrist ulnar deviation but not forearm pronation in the extensor carpi radialis brevis muscle.
Extensor carpi radialis brevis (ECRB) sarcomere length was measured in seven patients using intraoperative laser diffraction. Sarcomere length was measured with the forearm in one of four positions: wrist in neutral with regard to radial-ulnar deviation and forearm in neutral rotation, wrist in ulnar deviation and forearm in neutral rotation, wrist in neutral and forearm in pronation, and wrist...
متن کاملIntraoperative single-site sarcomere length measurement accurately reflects whole-muscle sarcomere length in the rabbit.
PURPOSE To compare single-site intraoperative sarcomere length values with sarcomere lengths measured from systematic sampling of the entire transferred muscle. METHODS The tendon of the rabbit second toe extensor muscle was transposed to the ankle extensor retinaculum under levels of stretch over the sarcomere length range of about 2.5 microm to about 4.0 microm. Intraoperative sarcomere len...
متن کاملSarcomere lengths in human extensor carpi radialis brevis measured by microendoscopy.
INTRODUCTION Second-harmonic generation microendoscopy is a minimally invasive technique to image sarcomeres and measure their lengths in humans, but motion artifact and low signal have limited the use of this novel technique. METHODS We discovered that an excitation wavelength of 960 nm maximized image signal; this enabled an image acquisition rate of 3 frames/s, which decreased motion artif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurophysiology
دوره 71 3 شماره
صفحات -
تاریخ انتشار 1994