Gel dosimetry is a promising technique for the implementation of 3D dose verification within the radiation therapy clinic, since it is the only methodology which provides comprehensive 3D dose measurement of conformal treatments such as Intensity Modulated Radiation Therapy (IMRT), Stereotactic radiosurgery (SRS) and Stereotactic Radiotherapy (SRT), and volumetric arc therapies (VMAT). In polymer gel dosimetry, monomer molecules polymerize and are fixed in the gel matrix when exposed to radiation. The spatial dose information thus can be obtained by gel imaging. Gel imaging methods which are currently under investigation are MRI, optical computed tomography and x-ray computed tomography. While promising, x-ray CT images of irradiated polymer gel exhibit low contrast due to small change in density that occurs during polymerization. The response of CT contrast to dose is weak and noise reduction is critical in order to achieve adequate dose resolution in gel dosimetry using x-ray computed tomography. Ideally, image noise is minimized using high tube current, long scan times and high number of image averages [Hilts et al 2005]. Digital image filtering is an effective method in reducing image noise while maintaining accurate spatial dose information. Generally it is performed in either frequency domain or spatial domain. In a previous work, several spatial filters were applied to Stereotactic Radiosurgery (SRS) irradiated polymer gel image [Hilts and Duzenli 2004]. In their study it was found that the two highest performing filters were the adaptive mean (Wiener) and smallest univalue segment assimilating nucleus (SUSAN). In another study a new method of signal to noise ratio (SNR) enhancement by 2D two-point maximum entropy regularization method (TPMEM) was investigated [Jirasek 2006]. However, a comprehensive examination of the best performing filters from these two studies has not been undertaken. Here, we test the Weiner and TPMEM digital filters on X-ray CT image of the irradiated PAGAT gel in order to reduce noise and improve dose resolution. This work builds off of previous studies and evaluates and compares the highest-performing filters from past individual works [Hilts and Duzenli 2004, Jirasek et al 2006].
منابع مشابه
Brachytherapy polymer gel dosimetry with xCT
ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...
متن کاملInvestigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کاملDesigning and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کاملEvaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry
Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...